Re: HP 5086-7906 YTO
Hi Razvan, thanks also for the service note. I have an E4407B, I had not noticed that it was the same second converter. Yves
By Yves Tardif · #146931 ·
Re: HP 141T Power Supply Help Needed
Comments are based on a scan of 00141-90914, 141T mainframe S/P 1615A, printed June 1976, file downloaded from BAMA. The positive side of C6 varies with mains voltage. If the regulator is working,
By Dave Wise · #146930 ·
Re: HP 5086-7906 YTO
Yves, thanks for the info about the 2nd converter After having installed the one bought on the bay I checked the original one on the bench and it seems to work normally I'm starting to suspect the
By alfa beta · #146929 ·
Re: HP 141T Power Supply Help Needed
Sounds good to me. Mike Sent: Friday, September 13, 2024 3:01 PM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T Power Supply Help Needed Dave, The
By Michael Bafaro · #146928 ·
Re: HP 141T Power Supply Help Needed
Dave, The schematic for the HP 141T shows all voltages referenced to ground.? If that is the case, you know the voltage at the positive side of C6.? It is listed as 5.9VDC.? So you can infer that
By Frank Mashockie · #146927 ·
8513A T/R test set attenuator question
Greetings, I have an 8510 VNA system running well with an 8515A S-parameter test set. I'm trying to convert a spare 8511A (sampler only box) into an 8513A T/R test set. That should just involve adding
By B Robert · #146926 ·
Re: HP 141T Power Supply Help Needed
Make sure you also replace the gas voltage reference (used in low serial number instruments) with a zener. My favorite is a TL431 plus a 60V-80V zener to stay within the TL431's max rating. The zener
By Dave Wise · #146925 ·
Re: HP 141T Power Supply Help Needed
Dave, Yes the sockets have caused intermittent connections. The sockets are form Keystone Electronics P/N 4608 which are still available. It appears that the brass contacts get annealed over time and
By Michael Bafaro · #146924 ·
Re: HP 141T Power Supply Help Needed
Take care with taking voltage measurements around the 141T PSU -12.6V regulator. It is not "ground referenced" at the input.? It is essentially a floating Positive regulator with it's Positive output
By Dave_G0WBX · #146923 ·
Re: HP 5086-7906 YTO
Hello Yves, This second converter assembly is also used in the 8563E and also ESA E4407B spectrum analyzers. In fact I think it is common for all 6.5/13.5/26.5GHz versions. Mine had failed in the
By Razvan Popescu · #146922 ·
Re: HP 5086-7906 YTO
Hi Adri, A friend of mine had a faulty 8595E, the problem comes from the option card 130. But I took the opportunity to look at the second converter, so here are some details on this module. Regards
By Yves Tardif · #146921 ·
Re: Thermal Couple attached to heat sink
That's Thermocouple, to be precise. Jim Ford, Laguna Hills, California, USA? Yahoo Mail: Search, Organize, Conquer
By Jim Ford · #146920 ·
Re: HP54610B No Display
Thank you for the suggestion. Unfortunately key-down power-up still gives a blank display so it looks like it may be a power supply fault.
By Steve Cheal · #146919 ·
Thermal Couple attached to heat sink
On the A7A3 board in the 8663A? Sig Generator there is a heat sink with a slot that holds a thermal coupler. The slot is filled with thermal compound. Underneath the TC and the heat sink was a square
By John Buie · #146918 ·
Re: HP54610B No Display
I can¡¯t remember if this was implemented in the firmware, but sometimes the ¡°key-down¡± power-up would clear some of the boondoggles and get the display back. Basically from a power-off state,
By Bob Groschen · #146917 ·
Re: HP54610B No Display
I don't know if the 546xx family of scopes suffers this problem, but the 545xx family has a battery maintaining the cal data and clock. When the battery dies, you get a short lived message on the
By BobH · #146916 ·
Re: HP 141T Power Supply Help Needed
Bill, CR1 and CR2 are mounted on the heat sink at the lower right side of the unit. These are stud mounted diodes. The anodes of these are connected to the power transformer with 2 heavy white wires.
By Michael Bafaro · #146915 ·
Re: HP 141T Power Supply Help Needed
Finally got this thing back on my bench and a little free time.? ?Assuming CR1 and CR2 are in the back left of the case near the diode board, I see about 17v here both on the AC and DC sides.? ?
By Bill Berzinskas · #146914 ·
Re: HP54610B No Display
Thanks, I¡¯m having the same thought.
By Steve Cheal · #146913 ·
Re: HP 8568B from hell to Heaven... a restoration story!
*The restoration of the HP 85662A was a bit more complicated.* In this case, both panels of the instrument were missing, along with the board covers and even the cover for the high-voltage module.