Re: HP/Altec 8050A Manual Needed
Yep, I've had a HP 15119A microphone around here forever and always wondered what it went to - the only reference I found some years ago was for a big HP airport noise survey system.? Then I saw
By
john fitzsimmons
·
#122000
·
|
Replacement of YIG in 83592B
Hi all, it looks that YIG from my HP83592B is dead. The original part is 5086-7337? 2,3-7,0GHz. I haven't found it on eBay yet, so my question is: can it be exchanged for any similar?
By
MatejBA
·
#121999
·
|
Re: HP/Altec 8050A Manual Needed
Ahhh, so YOU got that dead one that was on eBay, eh? I had my eye on it for awhile. I didn't grab it because I was unable to find any good documentation for it, only an 8-page data sheet with no
By
Dave McGuire
·
#121998
·
|
HP/Altec 8050A Manual Needed
Anyone have a service manual for this mid-70s Altec Lansing - made by HP - real time audio analyzer??? All I could find on the internet was a short pdf on how to use it.?? The trace is off the
By
john fitzsimmons
·
#121997
·
|
Re: power supply calibration 3325A
Just sent it via PM. Good luck. Joe Sent: Wednesday, January 26, 2022 2:59 PM To: [email protected] Subject: [HP-Agilent-Keysight-equipment] power supply calibration 3325A Does
By
J. L. Trantham
·
#121996
·
|
power supply calibration 3325A
Does anyone have page 5-2 of the HP3325A service manual referring to power supply calibration, which is missing from the manual downloaded from Agilent?
By
Franco Macci¨°
·
#121995
·
|
Re: Off-Topic Question: Programmed Test Sources, Inc.
What do you need specifically? I have several manuals 73 Bill wa4lav ________________________________ Sent: Wednesday, January 26, 2022 11:15 AM To: [email protected]
By
Fuqua, Bill L
·
#121994
·
|
Re: HP/AG/KS...... 3458A reference question about LTZ1000
victor---- have mailed you-- look at your spam box Fra: [email protected] [mailto:[email protected]] P? vegne af victor.silva via groups.io Sendt: 26.
By
hardyhansendk
·
#121993
·
|
Re: HP/AG/KS...... 3458A reference question about LTZ1000
Hardy, I interested in what you have to say. Please contact me at: "daejon1" AT yahoo.com
By
victor.silva
·
#121992
·
|
Re: Off-Topic Question: Programmed Test Sources, Inc.
PTS became part of Wavetek long ago, and maybe it's called something else now. There is a lot of overlap between the two brand model numbers, and it's confusing because there were so many varieties of
By
Ed Breya
·
#121991
·
|
HP 58503A GPSDO I look for Firmware Rev. E
Good morning, I am interested in the Firmware Rev.E for the ROMs AM29F010-120JI (U11 / 2L, U12 / 1L, U13 / 2M, U14 / 1M) of my HP 58503A. On the net I only found Rev. A If anyone has a copy (.BIN) it
By
maurit
·
#121990
·
|
Re: Off-Topic Question: Programmed Test Sources, Inc.
Shoot, ISTR that PTS got bought by some other company.? ?Anybody else know?? Good luck, Bruce!? ??? ? ? ? ? ?Jim Ford?Sent from my T-Mobile 4G LTE Device
By
Jim Ford
·
#121989
·
|
Re: Hp 140T luminosity issue
Probably an open-circuit resistor in the CRT luminosity control circuit. Start by checking R615 and R616. Remember to discharge high-voltage areas as necessary, prior to working on the display
By
Ken Nener
·
#121988
·
|
Off-Topic Question: Programmed Test Sources, Inc.
Does anyone know if Programmed Test Sources, Inc. is open and still in business?? I have contacted them by email and left a phone message, but have not heard back.? I am seeking information abut a
By
ebrucehunter
·
#121987
·
|
Hp 140T luminosity issue
My hp-140t mainframe gas developer and issue . The luminosity control in inoperative and the brightness remain fixed as you can see in the photo. Can you help me in troubleshooting?!
By
Andrea Liverani
·
#121986
·
|
Re: HP/AG/KS...... 3458A reference question about LTZ1000
Hi Victor Tried to contact you off group. Hardy Fra: [email protected] [mailto:[email protected]] P? vegne af victor.silva via groups.io Sendt: 26. januar
By
hardyhansendk
·
#121985
·
|
HP/AG/KS...... 3458A reference question about LTZ1000
Hi, I have a few reference boards for the 3458A that do not have the plastic cap around the LTZ1000 reference. Does anyone know where to source these?? They must be available for TO-99 packages, but
By
victor.silva
·
#121984
·
|
Re: 8640B Counter
That appears to be the case. Unless there is some obvious mechanical defect with one of them, auctions don't seem inclined to bother with individual pictures, just "representative" image.
By
Bill Martin
·
#121983
·
|
Re: 8640B Counter
I also have an 8640B with cracked gears. The first to cause issues was in the 001 AM oscillator option and I pondered what to replace it with. It's on the spindle of the tuning variable capacitor and
By
Alan Bain
·
#121982
·
|
Re: Restoring HP-141 mainframe
I would suggest cleaning the switches first. I've had that problem on one I use regularly. Gary Appel
By
Gary Appel
·
#121981
·
|