Re: HP8593A Power Supply repair
Hi,
Would strongly suggest you install a 350v AC rated X rated capacitor rather
than a 300v component, particularly if being used in a 220/240v AC
environment.
350v components are readily
By
Kit
·
#119866
·
|
Re: ESG3000A (E4421A) signal generator - datasheet for 1GG3 series amplifiers
HI Milan,
The CLIP is very useful.? It is nice that it includes all of the options too.? Thank you for making that available at a reasonable price.
?I guess the inductors were a bit lighter than
By
Tom B
·
#119865
·
|
Re: HP200CD oscillator
C8 and C9 are 0.47uF paper coupling capacitors which can leak current,
which will change the output tubes bias and cause them to conduct excessive
current. Those mica will fail shorted, or simply
By
Michael A. Terrell
·
#119864
·
|
Re: HP200CD oscillator
Mica caps short from silver migration. I used to see a lot of them going
bad in IF transformers when the gap got small enough to arc. The radio
sounded like heavy thunder. One TV transmitter that I
By
Michael A. Terrell
·
#119863
·
|
Re: HP ET8866 True RMS meter - any info on this?
That is true, and not for sale.
Bill Lauchlan
Sent: Wednesday, November 03, 2021 4:00 PM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP ET8866 True
By
bill.lauchlan171@...
·
#119862
·
|
Re: HP200CD oscillator
Leakage in C12 is unlikely to be a serious problem as it's a high value electrolytic in a low impedance part of the circuit and not in a position where leakage would make a difference to tube
By
Morris Odell
·
#119861
·
|
Re: HP8593A Power Supply repair
I'm currently working on an 8594E power supply, and replaced the RIFAs.
C103 C104 and C105 are 0.1uF x2 250V
I replaced them with these:
Mouser #:
By
Andrew Hakman
·
#119860
·
|
Re: HP8593A Power Supply repair
Hi Dave,
Thanks for the info! I?ll let you know what outcome will be
Best regards,
Mark
By
mark woud
·
#119859
·
|
Re: HP8593A Power Supply repair
Yes Mark, that should be close enough. Just be doubly sure that you're matching or exceeding the safety class, and staying within the same type (X vs Y).
Good luck. Man I do NOT like that
By
Dave McGuire
·
#119858
·
|
Re: WTB: PIC17C42A-33I/L or PIC17C42A-33E/L
PLCC only acceptable and only in Industrial or Extended temperature range. -JW is LONG gone
Sent: 03 November 2021 17:17
To: [email protected]
Subject: Re:
By
David C. Partridge
·
#119857
·
|
Re: HP8593A Power Supply repair
Hi Dave,
Thanks for yor quick response. Yes my whole house was smelling for some days. SO if I take e.g. 0,1 uF that will do?
Best regards,
Mark
By
mark woud
·
#119856
·
|
Re: HP8593A Power Supply repair
Ahh, a Rifa. Bet that smelled nice.
The capacitance of these line bypass capacitors is not at all critical. Just find one of the proper safety class and the right physical parameters, and it
By
Dave McGuire
·
#119855
·
|
Re: HP8593A Power Supply repair
Hi Roumen,
I have an HP8590 with the 0950-1977 power supply unit inside.
In the power supply the Class X capacitor has melted down. I want to replace it, but I can?t read the Farad value
By
mark woud
·
#119854
·
|
Re: HP ET8866 True RMS meter - any info on this?
HP used "ET-xxxx" for Electrical Tools, and "MT-xxxx" for mechanical tools. These were usually one-off things or built in very small numbers, but they were often designed and built with the same level
By
Joel Setton
·
#119853
·
|
Re: HP ET8866 True RMS meter - any info on this?
And¡documentation will be almost impossible to find and may have never
existed except in the tech¡¯s personal notes.
wrote:
By
Jeremy Nichols
·
#119852
·
|
Re: HP ET8866 True RMS meter - any info on this?
ET stands for Engineering Test. ETs were commonly built for in-house use at
HP manufacturing facilities and rarely if ever sold directly to customers.
Certainly possible a ¡°good customer¡± might
By
Jeremy Nichols
·
#119851
·
|
Re: 437B analog meter
I did not catch the earlier thread on the 437 meter. I will bet thats
exactly the same thing going on with my meter. Its a small cheap meter. Not
very HP at all.
Thanks for the
By
paulswed
·
#119850
·
|
Re: ESG3000A (E4421A) signal generator - datasheet for 1GG3 series amplifiers
Inductor was ignored coz i scanned CLIP with wrong settings...
Milan
By
Milan Vasic
·
#119849
·
|
Re: HP ET8866 True RMS meter - any info on this?
ET numbers usually meant custom in house test equipment of fixtures (and likely one of a kind, or very small custom run).
Daun
By
Daun Yeagley
·
#119848
·
|
Re: HP ET8866 True RMS meter - any info on this?
Jim,
Pictures would help. Any part numbers on the main board or display?
73,
Steve
WB?DBS
By
Steve - Home
·
#119847
·
|