¿ªÔÆÌåÓý

Re: BNC that does not have the bayonet lugs
Ok I will post a picture tomorrow as a bit late now Regards Paul Sent: 20 May 2025 23:00 To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] BNC that does not have
By Paul Bicknell · #151970 ·
Re: BNC that does not have the bayonet lugs
Hi Mike Thy can look like the standard SHV but that has bayonet lugs on Sent: 20 May 2025 22:39 To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] BNC that does
By Paul Bicknell · #151969 ·
Re: BNC that does not have the bayonet lugs
Picture ?
By f1ghb · #151968 ·
Re: BNC that does not have the bayonet lugs
SHVs have bayonet lugs. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By Dave McGuire · #151967 ·
Re: BNC that does not have the bayonet lugs
SHV? 73, Mike, Mike Stevens, G8CUL/F4VRB. Sent: 20 May 2025 22:05 To: [email protected] Subject: [HP-Agilent-Keysight-equipment] BNC that does not have the bayonet lugs Hi all a
By Mike · #151966 ·
BNC that does not have the bayonet lugs
Hi all a bit off base but has anyone ever come across a connector that is the same size and form as a BNC but it does not have the bayonet lugs and uses a locking grove where the lugs would be it is
By Paul Bicknell · #151965 ·
Re: HP 478A Thermistor Sensor. Input return loss and matching
I think some testing of any alternative capacitors would be required because MLCC type caps often have subtle package resonances and they can also develop transmission line type properties when
By jmr · #151964 ·
Re: HP 334A distortion analyser problem
Not specific to this device - but check power rails. Failed capacitors or deteriorated gain transistors in the power supply will cause more noise on the power rail - could be a simple fix . I would
By Maciej Kawalkowski · #151963 ·
Re: HP 8566B repair
Sorry: maybe I didn't explain myself well: in fact A3A8 is in test mode, as indicated on page 164 of the service manual (Jumper A3A8 TP1 SWP TO A3A9TP3). Anyway I replaced the ACLU module and things
By gsl@... · #151962 ·
HP 334A distortion analyser problem
I was wondering if someone has the idea about this problem: In voltmeter mode , just after starting it up, the needle will deflect from zero, for about 5% of the scale ( no input ). This will happen
By Goran Parezanovic · #151961 ·
Re: (OT?...) Sticky labels for aluminum and other typical materials panels
Maybe this is the t=right thread to ask if anyone knows of a truly Permanent marker ? If i write on polythene bags with a Sharpie it rubs off in a few weeks. A Biro is a little better but too narrow
By Adrian Godwin · #151960 ·
OFF TOPIC - JSR RM3500 automatic modulation meter manual
Date: Mon, 19 May 2025 12:44:52 -03 Does anyone have the manual for the JSR RM3500 automatic modulation meter? Thank you. Marcelo F. Ruiz
By Marcelo Ruiz · #151959 ·
Re: (OT?...) Sticky labels for aluminum and other typical materials panels
Custom front panels are a perennial pain, so a lot of people have tried different ways. You may get some useful ideas from this post and the links in that post.
By Tom Gardner · #151958 ·
Looking for manuals for Yokogawa-HP 4255A Universal Bridge
Hi all, I am thinking of maybe picking up a 4255A Universal Bridge for some fun, but I can't seem to find a manual for it anywhere. Does anyone have a copy of any user or service manuals for this
By Jared Cabot · #151957 ·
Re: YIG Oscillator Info?
Re YIG module power supplies. Many (most?) "Modern" YIG modules likely protect themselves (but you'd be wise to assume they do not) from incorrect power sequencing.? However... From personal hard won
By Dave_G0WBX · #151956 ·
Re: how to convert HP83711B to 83712B!
The 83711A/B was introduced in the early 1990¡¯s or late 1980¡¯s. The Spectrum Analyzer Division (Santa Rosa, CA) had converted the production line to run on 9000/382¡¯s by that time. I would
By Don Bitters · #151955 ·
Re: HP 478A Thermistor Sensor. Input return loss and matching
Yes, 1206 is rather large. I¡¯ve not opened up the 478A or the other thermistor sensor I have for use with the 432A, one goes to 10GHz and the other to 18 GHz, but I would check into smaller
By Jim Ford · #151954 ·
Re: HP 478A Thermistor Sensor. Input return loss and matching
Sorry, I made a typo the graph title should say inductance in nanohenries (nH) not uH. The measured Ls for the 1206 capacitor is 1 nH. Here's a simulation for the VSWR if the thermistors are not
By jmr · #151953 ·
Re: HP 478A Thermistor Sensor. Input return loss and matching
A couple of people have now mentioned that it's possible to swap the internal caps for 0.1uF parts. I'm still not sure what package will be suitable, especially for the series input cap. A 1206 SMD
By jmr · #151952 ·
Re: 5334A part reference
I've dumped the three UVPROMs from my counter. The ROMs are attached here in case they could ever be useful to anyone later on. The versions, as marked on the stickers, are: U17 - HPIB Controller:
By Ed Koloski · #151951 ·