¿ªÔÆÌåÓý

Date
Re: New doc about 180 oscilloscopes
Gianna this is incredible!? I'm currently working on a 182T with a 8557A plug-in.? Can I be greedy and ask for a Spectrum Analyzer section for this beautiful document?
By Frank Mashockie · #145097 ·
Re: New doc about 180 oscilloscopes
Buonasera Gianni, ho iniziato a leggere il suo lavoro, a pagina 4 mi sa che deve correggere l'unit¨¤ di misura delle dimensioni , sono cm , non mm By the way, ho lavorato in HP Italia dal 1976 al 1985
By Roberto Vegliach · #145096 ·
Re: New doc about 180 oscilloscopes
Some notes from my repairs; Some of the metal film resistors used in the voltage divider/feedback circuits in the PSU and the horizontal amplifier can drift high in value, or go open. The 4-071
By factory · #145095 ·
Re: New doc about 180 oscilloscopes
Thank you for doing the work on this. I was working for -hp- when the 180 came out. It was almost a world beater but not quite. I suppose I am more oriented toward "old stuff" because I am old. --
By Richard Knoppow · #145094 ·
New doc about 180 oscilloscopes
I continue with my perhaps-senseless activity of documenting old stuff. This is the draft about the 180/181 oscilloscopes: http://www.k100.biz/ebooks/180_draft.pdf Any contribution/correction welcome.
By Gianni Becattini · #145093 ·
Re: HP3048 data file format?
Feel free to swipe the 3048A code out of timelab.cpp if you like (which can be found in the installation directory written by the setup program at https://www.miles.io/timelab/beta.htm ). Search for
By John Miles · #145092 ·
Re: HP 8405A Vector Voltmeter Probes
Hi Andreas. I think it might be possible to use the dual diodes and they might perform better than the single diodes with lower package capacitance? It's worth a try at least. I also have some dual
By jmr · #145090 ·
Re: HP 8405A Vector Voltmeter Probes
Sadly, nothing significant to report from me. I tried putting a genuine 5082-2800 diode on the curve tracer and on the VNA and it is definitely a bit better (in terms of capacitance and dynamic
By jmr · #145089 ·
Re: VISA problems with ancient test equipment?
Hello Yves, thanks to your tutorial on how to get rid of "Unknown Instruments" in Keysight Commander I made some progress. Commander works fine now and when I tested your second programm (dated
By dk1vi · #145088 ·
Re: Several problems with Agilent 54810
Hello, I tested the 2 lamps of back lighting. I have infinity on the 2. *I think we are rather dealing with "neon" style lamps and not classical filament, which explains an infinite resistance*. (? if
By Gerard · #145087 ·
Re: HP 8970B with 346B Noise source - Error 13
[email protected]> wrote: The excess noise ratio (ENR) is reference to thermal noise at 290 K - not to 1 mW. Dr David Kirkby Ph.D Kirkby Microwave Ltd Email: drkirkby@... Web:
By Dr. David Kirkby, Kirkby Microwave Ltd · #145086 ·
Re: HP 8970B with 346B Noise source - Error 13
Am 27.06.2024 um 13:11 schrieb paulswed: *And 11dB ENR is not the same as 11dBm !*
By DF6NA Rainer · #145085 ·
Re: HP 8970B with 346B Noise source - Error 13
Hello Paul, The manual says to use the 346B/C for the calibration which are 15dB ENR sources. It also says you can use the 346A but you need to add +10dB of gain. So a minimum of +11dB sounds normal I
By Razvan Popescu · #145084 ·
Re: HP 8970B with 346B Noise source - Error 13
Razvan I appreciate your reply. Well thats a surprise. 11dbm as measured on a power meter like a HP436, or a spectrum analyzer? Thats 100 mw. I never would have thought to go that high for a input. I
By paulswed · #145083 ·
Re: HP3048 data file format?
Thank you very much Alan! With this I will probably succeed. My main goof was, that I was looking for 4 byte floats... Marko Cebokli
By Marko Cebokli · #145082 ·
Re: HP 8970B with 346B Noise source - Error 13
Hello Paul, I also use my units for Ham Radio and at least I have the 8970A working. I didn't have time to look at the voltages in the B model. I have the original HP noise source but as I said I am
By Razvan Popescu · #145081 ·
Re: HP3048 data file format?
The source code in HP Basic to the 3048 program is available and the load_results is as follows. It basically uses the ENTER command to do HPBASIC IO. The HP BASIC manual reminds us that in binary
By Alan Bain · #145080 ·
Re: 3562A Help/advice
The display module is the HP 1345A. There are two versions, one which includes display memory that it uses to continuously refresh the display, and the other version does not have the display memory,
By Philip Freidin · #145079 ·
Re: HP 8970B with 346B Noise source - Error 13
Razvan I don't have your answer but face a similar issue on my 8970a. Though I do not have any official HP noise source. I do have noise sources and amplifiers so have tried various levels all with
By paulswed · #145078 ·
Re: Artek Manuals - vacation announcement
Can you please confirm those dates? July 6th is not a Thursday. Thanks, Stan
By Stan · #145077 ·