YIG pinout
Does anyone have the pinout for the 5086-7267 YIG oscillator handy?
My google-fu seems to be weak today.
Thanks,
-Dave
--
Dave McGuire, AK4HZ
New Kensington, PA
By
Dave McGuire
·
#86262
·
|
Re: 3585B Spectrum Analyzer
So far I've removed all the boards I could that were relatively easy. I have not touched the ones that are under a metal panel identified as A and then a number. A31 or A32 for example.
I'm no
By
ve3poa@...
·
#86261
·
|
Re: Plan to deep cleaning my gear
?????? You have not said what equipment you want to clean. It does make a difference. I have detailed the method of washing employed at the -hp- service center a great many years ago but this
By
Richard Knoppow
·
#86260
·
|
Re: Plan to deep cleaning my gear
I find that Ronson lighter fluid, which is just naptha works very well.? This includes not only label goo, but a wide range of "dirt".? It's mild and doesn't hurt plastics (at least not any that
By
Daun Yeagley
·
#86259
·
|
Re: HP items for sale
Hi Tam, No, thank you.
Frank
By
Frank Hughes
·
#86258
·
|
Re: Plan to deep cleaning my gear
The only thing I'd wash with water and soap is the front panel itself
(completely removed from the instrument, and any pcbs or wiring harnesses
removed from it), any knobs once removed from the pots,
By
Andrew Hakman
·
#86257
·
|
Re: YIG device failure modes
Tobias,
The main coil is for pretune -- which brings the center frequency of the YTO to the YTO PLL's capturing range which is usually +/- 20~30mhz around the CF. The FM coil is used to perform the
By
Calvin Guan
·
#86256
·
|
Re: Plan to deep cleaning my gear
Thank a lot for all your inputs guys! My instruments work very well for their age. I just wanted to make them great again:)
After reading your posts, I figured I will stay away from using any
By
Calvin Guan
·
#86255
·
|
Re: Question about HP3586B and measuring Power.
The 3596 was used to measure carrier levels in a multiplexed system at 75 ohms. The 75 ohm input would be used to terminate a 75 ohm output directly. The 10k input would have been used to bridge a
By
Tom Miller <tmiller11147@...>
·
#86254
·
|
Question about HP3586B and measuring Power.
One of the inputs on the 3596B is a 75ohm, another is a 10k ohm//50pf.
I can understand with a Voltage across a 75 ohm resistor how to get
a power reading. What happens when you switch the unit to
By
lamontcranston17
·
#86253
·
|
Re: Just purchased HP 3586B--EBAY
Hi George, I don't know. I'll receive the unit this week, I'll see if I bought trouble or if I got a deal.
Qmavam
By
lamontcranston17
·
#86252
·
|
Re: Plan to deep cleaning my gear
I keep hearing folks here mentioning water penetration
of circuit board substrates, I think I can help you lay
that myth firmly to rest. The process of making pcb's
has always involved many long
By
Chuck Harris
·
#86251
·
|
Re: HP items for sale
Hello,
sorry for being a bit slow to respond here. The Fluke313 Sounds interesting - would you be willing to ship it inside the USA to a freight forwarder?
---
With best regards
Tam HANNA (emailing on
By
Tam Hanna
·
#86250
·
|
Re: Plan to deep cleaning my gear
I had to remove BI/Beckman trimpots from our products at somewhere around 2000 because they would fail after the boards were cleaned. We switched to Bourns, and the problem went away. BI denied that
By
Michael A. Terrell
·
#86249
·
|
Re: Plan to deep cleaning my gear
I agree with this. I have been involved in many product developments over
40 years ( not for HP) and would not use anything but >99% IPA or DI water,
and only if the parts are rated to be cleaned with
By
Mark Goldberg
·
#86248
·
|
Re: Plan to deep cleaning my gear
I understand the desire to try and get the insides to look like new! Like Paul, I guess I have 50+ bits of oldish HP and Tek equipment, but I'm not sure I would do what you intend, especially with
By
Adrian Nicol <fenland787a@...>
·
#86247
·
|
HP 5343A S/N 2440A Service Manual
Looking for a HP 5343A Service Manual for S/N 2440A prefix. All kinds a manuals for the 2014A prefix. I am working on issues with the 10Hz to 500Hz section of my counter and the A3 Direct Counter PCBA
By
Rich Gill
·
#86246
·
|
Wanted: HP1346A/HP1347A EPROMS and service manual
Hi,
Ansgar Kueckes have gotten hold of a prototype HP1347A used to produce the "NORAD" graphics for the Wargames movie, and it does not match the 1346/1347 OPM manual on Keysights homepage.
For
By
bsdphk
·
#86245
·
|
5342A: blown sampler?
Hi all,
one of my other projects I'm working on is a 5342A which does not count on the high frequency input.
I checked the sampler according to the service manual. I used a 34401A for the resistance
By
Tobias Pluess
·
#86244
·
|
Re: Plan to deep cleaning my gear
Hi Calvin
My recommendation is you just dust equipment out clean edge connectors and
service fan assemblies / motors / bearings
In short if it is not broken do not fix it I only use soap and water
By
Paul Bicknell
·
#86243
·
|