Re: HP/Agilent/Keysight 8478B thermistor mount
I haven¡¯t seen any 8478B used as transfer standard , we used them with some special option to calibrate the 50MHz reference on 43x series meters , for sensor calibration we used a weinschel system2
By Lothar baier <Lothar@...> · #126666 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
Could you have used a single point frequency measurement n the VNA? I know the 8510 will do that. But I am sure the experience was educational - thanks for the education - it would have taken me a bit
By Bruce · #126665 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
I actually have one of these and treat it VERY carefully whenever I use it - which is infrequently Cheers! Bruce Quoting Lothar baier <Lothar@...>:
By Bruce · #126664 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
I certainly would call $14K outrageously expensive. Cheers! Bruce Quoting Lothar baier <Lothar@...>:
By Bruce · #126663 ·
Re: HP 8662A Power up - overvoltage shutdown
Hi, Following the comments by G Edmonds in this thread he recommended loading the PSU -40V rail more heavily to resolve the PSU shutdown error occurring immediately after start-up. Pleased to say that
By Tony · #126662 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
They certainly can be, and certainly are, used as transfer standards. Further, NIST will calibrate them. (they won't calibrate any other type of RF power sensor, unless something has changed very
By Dave McGuire · #126661 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
i wouldnt call it a transfer standard , weinschel/tegam makes sensors that use the same principle that are heated (1109/1111)? that are used with system 2 units to calibrate sensors , they are
By Lothar baier <Lothar@...> · #126660 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
first of you have to consider that the 8478B just as the older 478 series requires a lot of manual assembly steps as it was designed in a time when there was no such thing as surface mount parts or
By Lothar baier <Lothar@...> · #126659 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
It is directed at a captive audience. This piece is used as the transfer standard for making power measurement calibrations and is required for certain procedures. If you want to play in a certain
By Bruce · #126658 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
Hello, There is one more issue to consider. Long lines give delays. Once I wanted to measure the loss of a coaxial cable on a vna. Was an interesting experience: no response. Until I realized the
By Harke Smits · #126657 ·
Re: HP 8662A Power up - overvoltage shutdown
Dan - Excellent ob - maybe you should publish the Gerber Files for the new motherboard ? Cheers! Bruce Quoting "Daniel Nelson via groups.io" <djn@...>:
By Bruce · #126656 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
OMG, who would have thought......................
By Ken Eckert · #126655 ·
HP/Agilent/Keysight 8478B thermistor mount
For those of you who possess the older (hopefully working and accurate) 478A coaxial thermistor mount it might come as a surprise that the price of the present replacement ¨C the Keysight 8478B mount
By Greg Muir · #126654 ·
Re: HP 8662A Power up - overvoltage shutdown
Tony: I also replaced the power supply with a group of Meanwell Supplies. Wrote it up. In the files section under: HP 8662A_8663A Pwr Supply Changeout.pdf (
By Daniel Nelson · #126653 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
One thing to consider is that RG213 is not phase stable so if you flex the cable after calibration it may affect your measurement Sent: Thursday, May 26, 2022 1:10 PM To:
By Lothar baier <Lothar@...> · #126652 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
Hi Karin, "Upper limit" is not as hard a cliff as your question presupposes. Whether or not a given length of cable is too much depends on your acceptance criteria. What are you trying to measure, and
By Tom Lee · #126651 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
You mention port extensions but then in the post you refer to calibration , I just want to point out that those are different things ! When you do a calibration on a VNA you move the reference plane
By Lothar baier <Lothar@...> · #126650 ·
Re: Info Need on a RF FET for a Agilent E4438C signal generator
The problem is finding a HEMT in SOT89 with 27dBm , used to those parts were made as driver or pre-driver for Power amps but this is all done with MMIC now , I remember seeing a GaN HEMT made by MACOM
By Lothar baier <Lothar@...> · #126649 ·
Limits of the Port Extension on the Cal screen for calibrating at end of cable
Hello Group: I have an 8753C and am wondering what the upper limit on cable length would be if I place the cal standards at the end of a cable to do remote measurement of S11.?? In other words I am
By Karin Johnson · #126648 ·
Re: E4407B RYTHM Repair / Replace
Hello Kalle and Bob I worked out a method of adjusting a bad RYTHM tower. That works for the HP8563E and for the E4407. They share the tower as far as I know. Problem is the E4407 cannot be calibrated
By Peter Hansen · #126647 ·