¿ªÔÆÌåÓý

Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable


Lothar baier
 

¿ªÔÆÌåÓý

You mention port extensions but then in the post you refer to calibration ,? I just want to point out that those are different things !

When you do a calibration on a VNA you move the reference plane to the reference plane of your connector/cal standard no other adjustments are needed.

Port extensions are a software correction that are normally used to move the reference plane AFTER a calibration has been performed , this is typically done when you work with fixtures or other situations where a calibration is not practical or possible

?

From: [email protected] <[email protected]> On Behalf Of Karin Johnson via groups.io
Sent: Thursday, May 26, 2022 11:46 AM
To: [email protected]
Subject: [HP-Agilent-Keysight-equipment] Limits of the Port Extension on the Cal screen for calibrating at end of cable

?

Hello Group:
I have an 8753C and am wondering what the upper limit on cable length would be if I place the cal standards at the end of a cable to do remote measurement of S11.?? In other words I am using SOL, with the cal standards placed at the end of a 100 foot length of RG-213.? Theoretically placing the measurement plane at the end of the cable.? I have already done this and the results seem to be accurate relative to an actual measurement at the that physical place.
I hope I have explained this issue sufficiently.?
Regards,
Karin Johnson??

BTW: I have had an account on the Keysight forums in the past and have recently tried to login to that site, but It won't let me.? Possibly password have changed, and I cannot create a new account.? I have posted with Keysight support and hope they return the email.?

Join [email protected] to automatically receive all group messages.