Re: Measuring Phase with Agilent E5062A ENA


 

开云体育

I don't know your name but that's a great idea, thank you.

Gedas, W8BYA

Gallery at 
Light travels faster than sound....
This is why some people appear bright until you hear them speak.
On 11/18/2018 1:44 AM, bownes wrote:

Have you tried displaying your results on a Smith chart?

Check out Dr Joel Dunsmore’s book, “Microwave Component Measurements” for more than you ever wanted to know on the subject.?

On Nov 18, 2018, at 01:00, Gedas <w8bya@...> wrote:

Thanks for that. It does in fact say phase is measured +/- 180 degrees. Earlier I ran a quick test using the expanded phase format and I think it is in fact exactly what I want. Below is the same cable swept from 100 MHz to 300 MHz. The -90 degree and -180 degree points appear to be at the right frequencies. So if it will help others, un-wrapping phase or wrapping phase is very closely related to the expanded phase display format option of this ENA model. Too bad the users manual is useless in discussing these and so many other neat features.

<expand-phase-enabled.png>


Gedas, W8BYA

Gallery at 
Light travels faster than sound....
This is why some people appear bright until you hear them speak.
On 11/17/2018 10:10 PM, nj902 wrote:
Gedas wrote: "Can someone point me to some reading material to help me understand how to measure phase ..."
------------------------------------------------------------------------------------------------------------------------------------------

Look for references on "unwrapped phase" measurement / display.

Like:

Join [email protected] to automatically receive all group messages.