Re: HP-8753E Power Cycles at Start Up


 

Re: Power Supply for 8753E

Peter:

Take a look at the + and - 15V supplies. If the filter cap there draws too much peak current during cycle peaks, the current limit shuts down the supply. I found this when putting in new capacitors and the 'better one' I put in with lower ESR casued this.?

So, do check the voltage drop with a scope on the current limit resistors.....


Dan in Chandler, AZ