Re: ADE25MH Mixer - warning #tinysa


 

¿ªÔÆÌåÓý

My ADE25 module has locations for caps on the inputs and outputs but they are stuffed with 0 ohm resistors..
It seems to work ok, should I be worried?? Should I put in caps?? What value.
It also has an unstuffed location for an R next to the C.? Same question.

What 3db pad are you talking about?
73,
Gary
WB6OGD


On 1/26/2020 2:13 PM, m0wid wrote:

Mixer problem - SOLVED

The ADE25 mixers are fine.? They work in a different way to the ADE1 and needed a capacitor to decouple from the 3dB pad.? The ADE1 have transformers, so no problem.? A good learning experience.

The spurs at the harmonic frequencies are I think really are there.? If spur reduction is turned on the levels of the harmonics and the fundamental change significantly each scan, so the readings cannot be trusted.? I can see the harmonic on my Hermes Lite 2 SDR.
If I run the signal through a low pass filter then the levels of the harmonics in Tiny-SA drop significantly, but they are still present.? Interestingly the Nano-VNA measures the attenuation by the filter at the harmononic frequency of around 30 db, but the signal on the spectrum only drops by half that.? Further investigation needed.? Adding a fixed 15db attenuator drops all the signals by roughly that amount.

73
Dave M0WID