Hi Gyula
I am using the latest version of TFT_eSPI available from the arduino library manager - 2.3.4.? Any version later than 2.2.16 should be fine.? I see 2.2.16 is not available in library manager so must have had some issues or have been very short lived.
Hi Jim - thanks for the info on compiler error if the rotary encoder is not selected.? Now fixed in my version here, will release an update once I have tested a few more of the options in my_SA.h
To all - I plan to change the way the set centre frequency works.? Currently it also adjusts the span to be twice that of the centre frequency.? I would rather the two were independent, so If I have a span of say 5Mhz set, the changing the centre will keep that span (unless it reaches the limits of the possible sweep frequencies), just change the centre frequency.? Also the focus menu command (Sweep/Focus Frequency) currently uses something called FOCUS_FACTOR defined in my_SA.h, so the span changes with frequency, which I find just weird.? I think this should be a fixed span set to give maximum useful resolution, eg 2.6kHz RBW and 290 data points = 754kHz.? This would be defined in my_SA.h as FOCUS_SPAN, so the user could set it as desired.? The span can always be adjusted afterwards of course.? Maybe 1MHz may be more sensible.? The marker Focus function has an extra menu level to select the span - this could also be done for the focus frequency menu item.? How would you like these menu items to work?
73
Dave M0WID
Dave
?