On Fri, Oct 25, 2024 at 09:25 PM, David C. Partridge wrote:
Paul, the entire log file was in the attachment to the earlier message.? The Firmware was 6.05
Yes it was! Seems that your Gemini doesn't like setting UTC time. The result of the command isn't received 10 seconds after the command was issued (I actually increased the serial timeouts in the later versions of Gemini.NET, it used to be 5 sec).
?
I don't know what to tell you. Try turning off the Set Gemini Time on Connect and see how far you get without the :Sc command being used and if any other commands cause problems.