Re: SpotCollector SPProb


 

+ AA6YQ comments below

The short path probability box on the Spotcollector 9.8.3 main panel has no entries,?as it used?to do. I don't know what I changed to cause this. On the configuration general tab, in the Propagation Prediction panel, the enable SNR box and for all stations boxes are checked. The default required SNR is set to 0 db. PropView 2.0.7 is open. On the config prediction tab, all bands except 60m are selected. The required SNR for CW is 10, for SSB 20, for FT8 -24.

What am I missing?

+ Thanks for the errorlog.txt file. I shows that in the General panel on the Configuration window's General tab, neither the "Capture location info from notes" nor the "Lookup missing location info" options are enabled. Without an accurate location, SpotCollector does not direct PropView to generate a forecast.

+ After you configure SpotCollector, I suggest that you direct the Launcher to create and populate a Workspace containing the settings for all of your DXLab applications. Then the next time something stops working as expected, you can direct the Launcher to recover those settings as a second diagnostic step after rebooting Windows. See

https://www.dxlabsuite.com/dxlabwiki/CreateUpdateWorkspace

? ? ? ?73,

? ? ? ? ? ? ?Dave, AA6YQ
?
?