Re: Leni conversion #3
here is the removed assumed bad T1 transformer.? I took the metal frame off already...I intend to pry inside to learn. I noticed on the top, a coating is missing on the pin 1/2 side.? it is coated
By Michael C · #621 ·
Re: Leni conversion #3
I will get this ENI working as an ENI.? Then I'll one day convert it to a LENi when the mood strikes me.? My mandatory COVID work from home policy is over and I have to start going back into the
By Michael C · #620 ·
Re: Leni conversion #3
Don't ever give up on the ENi '700, they can usually be salvaged, or at worst supply unobtainable parts for then next one.Hint: Take of the range selector knob. If it's original is says DAKA-WARE,
By Geo Dowell · #619 ·
Re: Leni conversion #3
Thanks Geo,? ?read all your responses, got it!? ?will check resistances as described. and yes this failed one I have was dunked in something looks like shellac.
By Michael C · #618 ·
Re: Leni conversion #3
That's why this Group exists Michael,Please report your findings back for other to read too.ENi especially used a great many different transformers. They came out a few years later than all the
By Geo Dowell · #617 ·
Re: Leni conversion #3
forgot to say, always use resistance, don't trust continuity checker.Geo
By Geo Dowell · #616 ·
Re: Leni conversion #3
By Geo Dowell · #615 ·
Re: Leni conversion #3
You won't regret having those Michael C. !One day they might be worth their weight in gold.Geo
By Geo Dowell · #614 ·
Re: Leni conversion #3
That's the absolute best way to test them Michael,congratulations! . I forgot this last message, also check one winding of each coil against the frame of the transformer, there should be and must be
By Geo Dowell · #613 ·
Re: Leni conversion #3
hi Geo,? ?no I did not check between windings.? ?How does that work..? ? ? pin 2 to 3...? ? ?pin 4 to 5?
By Michael C · #612 ·
Re: Leni conversion #3
I just bought 2 of them.? and now I know how to check them before installing.? ?thanks all.
Re: Leni conversion #3
Ooop! Maybe. Maybe not. Infinity would be bad for sure, did you remember to check between the winding? None of the should have resistance to the other ones.Although I have checked a few recently and
By Geo Dowell · #610 ·
Re: Leni conversion #3
Michael, Lenox is the CDV-700 expert. I recommend buy the transformers too, all of them if you can. (and quick, once this is out they'll be gone in an instant)Thanks, Lenox, for that "inside tip".Very
By Geo Dowell · #609 ·
Re: Leni conversion #3
hi Lenox, the ENI transformer just sits flush on the board and held on by the six wire pins through the board.? ?and it looks to my untrained eyes that the Lionel uses the same 3 winding transformer
Re: Leni conversion #3
Hi, Michael, https://www.ebay.com/itm/265620413544?hash=item3dd835dc68:g:QxkAAOSwGExiQczb These appear to be Lionel transformers. However, I once used one in a Victoreen CD V-700 and it worked fine.
By Lenox Carruth · #607 ·
Re: Leni conversion #3
*ok, bad transformer. Multimeter continuity check:? ? pins 1-2? 1.826 no beep.? ?pins 3-4 good.? pins 5-6 good. * multimeter resistance checks:? pins 1-2 6.5kohms;? pins 3-4 .005 kohm;? pins
Re: Leni conversion #3
By Geo Dowell · #605 ·
Re: Leni conversion #3
Correct on the pins Michael C.Linkhttps://www.qsl.net/k0ff/LENi_Geiger_Counter/When someone stumbles across the obove link, we need a better rendition of the schematics of both ENi and Lionel
By Geo Dowell · #604 ·
Re: Barringer Hill
I think a guy named Frank Roberts used to guide groups prospecting for pegmatites in the? Badu hill? area.? Do you know of any public land in the Llano uplift counties that might be good for such
By Mike L. · #603 ·
Re: FOCUS THREAD: CDV-700 ENi brand HV Transformer info
Electro-Neutronics inc (ENi) CDV-700 HV transformer failure modes and other data: H ad to measure the resistance of the secondary for an overseas friend yesterday , 3730 Ohms from memory.
By Geo Dowell · #602 ·