Re: RF Noise sniffer
https://www.aliexpress.us/item/3256805914126548.html?spm=a2g0o.detail.0.0.27e12F1x2F1xPq&gps-id=pcDetailTopMoreOtherSeller&scm=1007.40050.362094.0&scm_id=1007.40050.362094.0&scm-url=1007.40050.362094.
By
David Fainitski
·
#2627
·
|
Re: RF Noise sniffer
Hi, Bill
I am sure, an SDR with a wide visual panorama is the best.
Something like RSP or
By
David Fainitski
·
#2626
·
|
Re: RF Noise sniffer
old AM radio ?
By
mike
·
#2625
·
|
RF Noise sniffer
Recommendations for an inexpensive broad band HF RF 0-30mhz RF Noise sniffer (no kits). May be a spectrum analyzer? NanoVNA? TinySA?
Will be used to chase down RF noise.
TNX Bill, WA2WIO
By
Bill WA2WIO
·
#2624
·
|
uSDX+ high base noise level issue
Suffering an S5+ base noise level. Noise filter set at 2. Vol set at 10.
Any advise on how to reduce the static level?
TNX Bill WA2WIO
By
Bill WA2WIO
·
#2623
·
|
Re: winding toroids - not seeing what I expect.
Thank you.
Yes. Opened a support ticket. Below 1uH, it does not work well. The meter is autoranging. So cannot pick the range.
I have another meter that has a 2uH range coming
By
Michael P
·
#2622
·
|
Re: winding toroids - not seeing what I expect.
Hi, Michael
Most likely the autamatic range select does not work properly.
Try to select 40uH range manually and do a calibration on this range.
I can say something stupid, i am not familiar with that
By
David Fainitski
·
#2621
·
|
Re: How is the tuner getting the L and C information while tuning?
Hi.
That's just a script with math. You can set up your own LC values in the pic cells while progtamming.
By
David Fainitski
·
#2618
·
|
How is the tuner getting the L and C information while tuning?
Hello,
This has probably been answered before, but I am a bit late in the game with this project.? Does the tuner take the LC values on screen from script by doing the math by looking at the fixed
By
N2BRG
·
#2617
·
|
Re: winding toroids - not seeing what I expect.
Toroid cores uH values can vary depending on how they are wound. If you scrunch all the turns together, the inductance is higher. Take a look at page 4 of 'Q-Curves' on the Micrometals
By
va3rr
·
#2616
·
|
winding toroids - not seeing what I expect.
To make sure I am winding correctly I am trying to measure the toroids with. a B&K 880
One confusing point is called for inductance is 0.45uH for L4.? But multiple the calculators call for 9
By
Michael P
·
#2615
·
|
Re: Change Turn on Press Timer
Ok, thanks David.
I¡¯ve ordered a replacement and as long as this one doesn¡¯t lock up or turn itself off I can get along fine without the change in button behavior.
Thanks for all your work on
By
Randy Paulson
·
#2614
·
|
Re: ATU10-New Dipole tune
Hi, Bill
You can disable automatic mode changing some cell in the FW hex file.
After that you can use ATU-10 like simple SWR meter to build curves.
By
David Fainitski
·
#2613
·
|
Re: Change Turn on Press Timer
Hi. No, that is not so easy, you can do changing button function and recompile FW with MikroE MikroC compilator.
By
David Fainitski
·
#2612
·
|
Re: ATU10-New Dipole tune
Thank you Mike for your response. I am running QRP (1-3watts) with a USDR type xcvr. I have a HeathKit HM-102 200w/2000w SWR Bridge. I am trying to avoid having to go buy a LP swr bridge. My thought
By
Bill WA2WIO
·
#2611
·
|
Re: ATU10-New Dipole tune
Bill
The ATU-10 doesn't have a bypass mode in the traditional sense. After a reset, it will wait unti it sees TX power that causes the directional coupler to report a VSWR greater than the programmed
By
Al Scanandoah
·
#2610
·
|
ATU10-New Dipole tune
I installed a new 40m dipole and want to tune it. Need to measure and chart
the SWR curve. Can I use the ATU10 SWR feature with the tuner in a bi-pass
mode? How would I go about this?
Thank you,
By
Bill WA2WIO
·
#2609
·
|
Re: Change Turn on Press Timer
Greetings David.
Yes that is correct.
Is there a way in FW to change those timers?
I'm just me, but I would prefer a short press for tune, 1 Sec to power off, and 3 sec to reset.
Thanks!
By
Randy Paulson
·
#2608
·
|
Re: Change Turn on Press Timer
Hi, Randy
It is definitely more then 1 sec now. About 3 sec,
Short press for reset, 1 sec for tune, 3 sec for turn it off.
By
David Fainitski
·
#2607
·
|
Re: AT-10 Random Errant Pixels and Lock Ups.
Hi, Randy
That issue is not in the FW. Thats a hardware, interferences to the Oled controller.
By
David Fainitski
·
#2606
·
|