Re: Cell 04 (EEPRON) value to set the threshold settings in automatic mode
Hi, David,
I knew that.? But? I was also wondering: why on other bands where the lowest found vswr is around 1.5 I've never experienced the same behavior?
But, yes I will definitely set it to a much higher number: 20.
One final question:
When cell number 4 is 13 and the lowest SWR is 2:1 for example, what will be the vswr value the will force an automatic tuning???
Thanks a lot for your answer!
Greetings from Rio. 73
Paulo Em qua., 16 de out. de 2024 12:34, David Fainitski via <rolin791= [email protected]> escreveu:
toggle quoted message
Show quoted text
Hi, Paulo?
Yes, you can change the value in the cell 04. This is a SWR needed to be changed to trigger a tuning process.
An example, your current SWR is 1.5. Value 13 is meaning the tune will start with new SWR 1.8.
|