Re: Cell 04 (EEPRON) value to set the threshold settings in automatic mode


 

Hi, David,

I knew that.?
But? I was also wondering: why on other bands where the lowest found vswr is around 1.5 I've never experienced the same behavior?

But, yes I will definitely set it to a much higher number: 20.

One final question:

When cell number 4 is 13 and the lowest SWR is 2:1 for example, what will be the vswr value the will force an automatic tuning???

Thanks a lot for your answer!

Greetings from Rio.
73

Paulo

Em qua., 16 de out. de 2024 12:34, David Fainitski via <rolin791=[email protected]> escreveu:

Hi, Paulo?
Yes, you can change the value in the cell 04. This is a SWR needed to be changed to trigger a tuning process.
An example, your current SWR is 1.5. Value 13 is meaning the tune will start with new SWR 1.8.

Join [email protected] to automatically receive all group messages.