Re: Repairing faulty AT sensor


 

Number 2 works rather well. I think we should not worry about 2 (or should we? they - 15 is in series).

Anyway, on number 2 RC is connected to -15 and probably to T3. RB is connected to T3 and R4 (to the second printed track from the left). But as I said - that circuit works. The glue is more like a silicon stuff to keep everything in place and protect the joints.


The circuit 1 is defective.R2 has very little overall resistance - around 0.7V as mentioned before.