This is what I'm leaning towards, and barring the availability of
anything more than rudimentary test equipment would be the easiest
to try. If replacement of D1301 doesn't solve the problem then the
fault is with Q1301.
73 - Fred, N8YX
On 5/7/20 9:58 AM, Rex K0KP wrote:
toggle quoted message
Show quoted text
I recall having this problem many years ago, kind of fuzzy, but as
I recall I simply replaced the triac and all was good again.? That
would be easy to try.? Good luck.? It is very nice to see this
group helping one another.? ?73
_._,_._,_