Am Mo., 12. Juni 2023 um 18:07?Uhr schrieb Hans Hübner <hans.huebner@...>:
Checking the PSU, I found that the +12V rail is dead,?+5V and -12V are fine and judging from the SCSI2SD activity, it seems that the machine boots as well.? I guess I'll bodge a boost converter into the +5V rail to generate the?+12V needed to drive the AUI transceiver and the serial ports.? These SPARCstation IPC/IPX power supplies are really sad :(