MRC DCC compatability with Digitrax
Group, I realize this group is more for wiring problems, but please hear me out.? I have posted to both the Digitrax and MRC DCC groups with no definitive ideas. ? Background: I am (supposedly) the DCC guru of a club that uses Digitrax system. (DCS200 and 2 DB150 boosters). We run a variety of decoder equipped locos of all the major manufacturers with no problems. One club member has a Prodigy Advanced system with add on WIFI. He has several modern diesels from different manufacturers (Athearn Genesis, Kato, Walthers, and Scale Trains). Some have factory installed sound decoders while others have after market ones. ESU and Soundtraxx decoders. His locos have 4-digit addresses and are not consisted either by advanced or universal consisting.? His locos run quite well on his home layout. ? The problem is that none of these diesels will run on our club Digitrax layout. One loco has the headlight come on when it is put on the track. None have sound, lighting or movement control. Needless to say, this is quite frustrating to our member. ? We have resset the decoders with no change. ? One response had heard of a similar problem at a club layout. A CV had to be changed, but the responder couldn¡¯t remember specifics. ? So¡Can anyone on this group help? Thanks much for your help. Lee ? |
Lee,
?
At this point, you don't really have an MRC vs. Digitrax issue.
?
If you reset the locomotives, the should run on the Digitrax system as address 3.?
I've seen at least one funky decoder.? Our club got a loco from someone who had passed away that we could not set to address 3 on our NCE PowerCab system.? We did get it set on a Bachmann system.? I don't know what the Bachmann system was doing differently than what I could do on the NCE system.
?
I know there are decoders that can only be changed as ops mode programing on the main.? I don't recall which brands are like this.
?
Allan
Wiring for DCC
?
?
? |
Yes. Some decoders require OPS, some Direct and some POM. Just to change the loco number from 03 to xxxx. But there is no logical reason for a loco to work on MRC and not on Digitrax/or NCE.
All locos on "03"/from reset should operate on any system. That's what the NMRA set up and "all manufacturers must adhere to".
There must be something else that's the problem.
This is what I was taught and have always heard. So if someone has a better solution, we need it here.
Morgan Bilbo, DCC since 8/18. Model PRR 1952. |
¿ªÔÆÌåÓýI recently had a unit work fine at home, but it didn¡¯t want to respond at the club until we had cleared the consisting¡
|