Re: Auto Reverser (s)
Hi Ted
For the AR1 Manual, see:
https://www.digitrax.com/media/apps/products/autoreversing/ar1/documents/AR1.pdf
Regards
Marcus
Sent: Tuesday, 22 June 2021 11:32 AM
To:
By
Marcus Ammann
·
#12825
·
|
Re: Auto Reverser (s)
Thx for everyone's input. Tried a different one and it worked! I guess the
other one has become faulty and cannot likely be fixed. Would still
appreciate hearing from Alan as to how they are
By
Ted Atkinson
·
#12824
·
|
Re: Staging yard wiring question
Scott
For me, a bus(or sub-bus) connects many feeder wires as one electrical component; feeder wires run from the bus to individual rail segments.? Feeders always have one end attached to a rail. In
By
Blair
·
#12823
·
|
Re: 1156 Bulb Short Protection and Powercab
And I'm with John. Until a good solution comes along - but I also want a reasonable price. You can't compare a bulb with a good circuit breaker. But. The price must be within my budget. And that bulb
By
PennsyNut
·
#12822
·
|
Re: Staging yard wiring question
Sorry.
You said bus wire when I think you mean feeder wire, thus the confusion.
Scott Haycock
Modeling Tarheel country in the Land of Enchantment
By
Scott H. Haycock
·
#12821
·
|
Re: Staging yard wiring question
Hi Blair,
In my opinion, there can never be too many feeders to any rail. It may seem like a lot more work on paper, but I have found, once you get the rhythm going, it is no big deal. On my layout I
By
emrldsky <azMikeG@...>
·
#12820
·
|
Re: Staging yard wiring question
Why is it that no one reads the original post any more?? As I said, there is a relay, and a block detector, for one rail of each track.? My question was focused on the best wiring of the second,
By
Blair
·
#12819
·
|
Re: Staging yard wiring question
I did this exact thing for the exactly the same reason. In doing so, it prevents the command station from seeing a surge in voltage and therefore, a total power shut down.
To make the routing of
By
george hohon3
·
#12818
·
|
Re: Staging yard wiring question
that was covered by the fact that I'm wiring one rail individually, and switching them when selected.? (i.e. when a turnout is aligned for a track, at either end, the track is energized).
By
Blair
·
#12817
·
|
Re: Staging yard wiring question
One reason to have each track separately wired would be to prevent all the sound equipped engines in the yard from starting up at the same time when you power up!
Scott Haycock
Modeling Tarheel
By
Scott H. Haycock
·
#12816
·
|
Re: Staging yard wiring question
thanks, Steve, for the sanity check.? That's what I thought, but...? So the only reason I might run separate runs is if I want to provide the flexibility to split the yard across two boosters at
By
Blair
·
#12815
·
|
Re: Auto Reverser (s)
Ted,
It sounds like your AR1 is not reversing when it should.? I think it is adjustable.? Try adjusting it.
Allan Gartner
Wiring for DCC
By
Allan AE2V
·
#12814
·
|
Re: Auto Reverser (s)
Maybe swap in a different AR1?? It's possible the relay contacts are welded in the unit, and it's unable to properly switch states.? Or, the circuit is fried completely, and unable to energize the
By
Blair
·
#12813
·
|
Re: Auto Reverser (s)
What else changed in your system Ted?
Maybe new Booster? New Short Detection? (add a PSX-1 or other?)
anything?
I know for me.. and the HMRC (Housatonic Model Railway Club) layout.. I had
a great
By
BillMellott <wmellott@...>
·
#12812
·
|
Re: Staging yard wiring question
Nothing at all to prevent you from using a "common" bus for the other rail on each of those tracks.
If you think about it, whether you install a second "block" bus for that other rail or tie them
By
Steve Haas
·
#12811
·
|
Auto Reverser (s)
Had used a Digitrax AR1 Auto Reverse Controller, prior to upgrading bus to
14 gauge from 16 gauge, on one reversing section and it worked fine. Now
it allows locos thru one end of the loop but shorts
By
Ted Atkinson
·
#12810
·
|
Staging yard wiring question
I have a 12-track staging yard; in order to implement detection, I need to run one bus wire for each track's front rail, having run that wire through both an on/off switch and a current detector. All
By
Blair
·
#12809
·
|
Re: 1156 Bulb Short Protection and Powercab
I have to agree with Morgan. I do run NCE but the 1156 did not work for me. I use the 1157¡¯s brake filament. One filament of the 1157 is equivalent to the 1156 and the second is a higher current.
By
John Bauchiero <john@...>
·
#12808
·
|
Re: 1156 Bulb Short Protection and Powercab
Just for those of y'all that don't use NCE. I use a 1157 bulb with my Digitrax and it works like it's supposed to. I mounted it at the center of my layout/command station, visible all long my shelf
By
PennsyNut
·
#12807
·
|
Re: 1156 Bulb Short Protection and Powercab
Thanks Ken.
By
Dave Hamernik
·
#12806
·
|