¿ªÔÆÌåÓýHi Joe You already got an answer from Eric, as the frequency must be 5.34GHz within 1KHz. However, the predefined harmonic offset is after a firmware update set to 10.5 and is not far away to what is created during the calibration above 5.34GHz, so is not essential except you want to measure above 5.35GHz with best possible accuracy. However, there is a simple work around as if you enable ultra mode as choose center frequency 5.34GHz and span 100MHz. Then you apply a signal from a signal generator on one half or one third frequency, and tune the signal frequency so you see a signal 10MHz lower=5.33GHz and 10MHz higher 5.35GHz. The levels shall be equal on either side of 5.35GHz and if not the tune the leveloffset harmonic via a terminal command e.g. change the leveloffset harmonic from 10.5 to 10 as a start, and see if that was in the right direct for the level at 5.35GHz. The level at 5.33GHz does not change. Kind regards Kurt ??????? ? Fra: [email protected] <[email protected]> P? vegne af josephlevy via groups.io ? Hi Erik. |