On Tue, Dec 13, 2022 at 04:37 AM, davebb123456 wrote:
running the latest firmware on a tinysa i am getting, test 7 flatness fail,
Can you share a screen capture or photo of test 7 failing.
The fail is due to overly strict criteria as we are only now collecting statistical data on the correct boundaries for test 7
and the output power is 7-8dbm lower then displayed, measured with a HP test set,
Do you mean tinySA output level is 7-8dBm lower? of the level as measured by the tinySA?
is this why it is failing test 7 flatness ?
No, see description above
can i increase the output power to match the tinysa read out, or is this a fault with one of the parts,
Which output power? tinysa??
We are busy creating a new FW that uses an updated set of output calibrations matching with the latest production samples.
?
--
For more info on the tinySA go to https://tinysa.org/wiki/