On Fri, Oct 2, 2020 at 12:40 PM, charlie carroll wrote:
In the upper left corner of the display you can set Start, Stop frequencies.? Is the TinySA supposed to be set to these frequencies?? The app's display changes according to the settings.? But, the TinySA itself does not change.
thanks
Charlie,
? ?tinySA-App uses the very efficient 'scanraw' command for data transfers. This is a binary format that has the advantage of not being limited to the 290 point display limit of the tinySA.?
? In your example, if the display of the tinySA is set to, for instance, 100k-350MHz and in tinySA-App you enter start and end frequencies of 1 and 31 MHz with 500 scan points the 'scanraw' command will acquire 500 points of data between 1 and 31MHz and display the data in a graph without disturbing the tinySA's display.??
?If you actually want to remotely control the tinySA sweep settings you bring up the tinySA-App Comms window and enter 'sweep' commands from there.
??

- Herb