Date
Re: Nanovna on Zorin OS
Thanks! I will do that.
By py2mta@... · #14022 ·
Re: Calibration quick one
Sorry guys and gals: How many times must this point be made? ????????????? Resolution (point-to-point spacing) = Frequency Range / 101. Not using external
By W0LEV · #14021 ·
Re: Calibration quick one
Not needed systematically if you use nanovna-saver. If you do a calibration between 1 and 900 Mhz with 20 segments (for instance) this makes 20X101 points = 2020 points or 1 point every 450 khz
By Peter Ide-Kostic <on7yi.pik973@...> · #14020 ·
Re: What does S21 mean in this context?
You would do a bit better to cap the second port with the 50-ohm load. S21 or S12 are not involved in what you are doing. Any reading is due to crosstalk and lack of shielding and proper decoupling
By W0LEV · #14019 ·
Re: Calibration quick one
Since the NanoVNA only has 101 point sweeps, when you calibrate from1 to 900 MHz, you have calibrated points every 8.9 MHz. So, suppose you wanted to sweep a 7 MHz bandpass filter for a 40 meter rig
By Jim Allyn - N7JA · #14018 ·
Re: Where to buy in US and other questions #shielding #buying
On Tue, Jun 2, 2020 at 09:56 AM, Larry Rothman wrote: I contacted R&L about buying and shipping a Nanovna-H4 to Canada. They sell the H4 for $60US but they quoted me $30US for USPS shipping to Toronto
By hwalker · #14017 ·
Re: Dark Mode
Use Display setup -- *** nothing is permanent only change ( http://ha3hz.hu/ ) ***
By Gyula Molnar · #14016 ·
Re: What does S21 mean in this context?
S21 isn't used in your antenna tuning context. You can turn off this trace to avoid confusion, unless you like the "modern art" it produces on the screen. The USB C port doesn't need to speak "To-Go"
By Dave W6OQ · #14015 ·
Re: Calibration quick one
Answer: YES. When the range changes, calibration must be performed. The number of calibration / measurement points is 101 on the basic unit. 73, Gyula HA3HZ -- *** read more on this site (
By Gyula Molnar · #14014 ·
Re: What does S21 mean in this context?
Your photo shows S21 phase on the display. This is the phase of the (weak) S21 leakage. If you change it to magnitude, you will see the leakage signal strength. When using the VNA as an antenna
By John Gord · #14013 ·
Re: Calibration quick one
Recalibrate. The number of calibration points is limited. w.
By Helmut Wabnig · #14012 ·
Calibration quick one
Hello all, Quick question please. If I calibrate my nano from 1Mhz to 900Mhz and I want to change my frequency to 7Mhz to 71Mhz do i have to calibrate again or is this still in range of the original
By sidebores@... · #14011 ·
Re: What does S21 mean in this context?
Are you aware there is a -F variant specific group? Regarding S21 have you made a SOLT calibration in the frequency range of interest? A ter?a, 2/06/2020, 19:52, <wsanders@...> escreveu:
By CT2FZI · #14010 ·
What does S21 mean in this context?
I am using the NanoVNA-F to tune a 75m mobile antenna (see picture.) There is an interesting pattern on the S21 trace. The VNA has been calibrated only using SOL (short-open-load). I have S21 "capped"
By wsanders@... · #14009 ·
Re: What apps use Touchstone files? #applications
[email protected]> wrote: That's not the whole story. A Touchstone file can store data in other formats too - Y, Z, G or H parameters. However, S parameters is the most common. I would be interested
By Dr. David Kirkby, Kirkby Microwave Ltd · #14008 ·
Re: out of "Presentation on the NanoVNA for the raileigh Radio Society", Now: "False Return Loss Calculations"
Does all of this mean that the RL on the NanoVNA and VNA Saver are wrong and should be positive??Deon
By RandMental · #14007 ·
Re: PC software with "CW" function SOLVED with avvidclif's freq command !
Herb, Thank you for your message and? explanations for use above 300 Mhz. Most of time, i use the VNA from 1.8 to 146 MHz but sometimes until 440 MHz. For this reason, i will follow your
By Rudolf Schaffer · #14006 ·
Re: What apps use Touchstone files? #applications
BTW, I created a guide for nanoVNA users to use QUCS here https://hexandflex.com/2020/01/11/impedance-matching-with-qucs-studio-and-vna/
By HexAndFlex · #14005 ·
Re: What apps use Touchstone files? #applications
QUCS studio has a simulation block that accepts Touchstone files. It's the closest free software to ADS. I suspect you can also load them into the free demo CopperMountain VNA software.
By HexAndFlex · #14004 ·
Re: VNA Calibration Reference Box #calibration
Here are some tips for those that may wish to duplicate this box design which has a front panel size of 92mm x 38mm: - The hole centers for the two end connectors, "L" & "THRU" are 15mm from the ends.
By Tom VA7TA · #14003 ·