Re: Just opened the box and charged the unit now all I get is a white screen!!!!!
Mel, That is exactly what happens if one shorts the boot contacts next to the battery connector when switching on. Therefore, check that the boot contacts are not shorted. Stefan. [email protected]>
By stefan baartman · #19286 ·
Getting NanoVNA-Saver to run on my Mac #nanovna-saver
I am not the best at using terminal, but, to the best of my knowledge, I've done all that I am supposed to do to get to the NanoVNA-Saver executable and I STILL cannot get a .dmg file. Anybody have a
By Dee Hester <deehester@...> · #19285 ·
Re: Just opened the box and charged the unit now all I get is a white screen!!!!!
Check that the Boot contacts aren't shorted . . . [email protected]> wrote:
By stefan baartman · #19284 ·
Re: My $165,000 VNA
Having retired after 40 years in the telecom industry I can attest to this. We used to design and build our own systems. Now all applications reside on third party cloud computing platforms. Another
By Mike N2MS · #19283 ·
Re: NanoVNA WINDOWS OR ANDROID SOFTWARE
Hi Clyde, Piero, and othersJust to put a word in about Saver 0.3.8 and FW ver 1.0.39, I have not had any problems getting them to work together. NanoVNA-H4, Win 10 Pro latest update on a Dell Tower
By Walt WA7SDY · #19282 ·
Re: Setting up NanoVNA-H for First Use
The Cal 0 location is loaded when you restart, so to save a particular Trace setup, just do CAL/SAVE 0 if you want to automatically start with that setup. It will be saved with whatever calibration is
By John Gord · #19281 ·
Re: Setting up NanoVNA-H for First Use
OK, viewed the videos and now have the firmware updated to Hyugun's last, Feb 2020. Things working as expected, however: 1. My NanoH4 saves the scan start and stop frequencies OK, so when I turn the
By Steve Johnson · #19280 ·
Re: Just opened the box and charged the unit now all I get is a white screen!!!!!
Should have said that this my third one for a Christmas gift. What I am asking is there a HARD reset on the PCB? Thanks. Mel, K6KBE
By Mel Farrer <farrerfolks@...> · #19279 ·
Re: How to go to the FILE or WIKI page?
Hello Kees, I tried each of the links you provided, and was directed to the correct file pages each time. Not sure why you are experiencing a problem. Clyde KC7BJE
By Clyde Lambert · #19278 ·
Re: NanoVNA WINDOWS OR ANDROID SOFTWARE
Hello Piero, I was using NanoVNA H firmware, 1.0.39.dfu FW and nanovna-saver 0.3.8 This combo did not work. I could not get the Software to recognize the VNA no mater what I tried. Even though the FW
By Clyde Lambert · #19277 ·
Re: NanoVNA-H low frequency errors #calibration #firmware #nanovna-h
Hello, Tell me if you have checked the SOL terminations on another VNA? Also, I found that I needed a warm and fuzzy check when using the VNA so built up a couple reactive terminations. That is, a PCB
By Mel Farrer <farrerfolks@...> · #19276 ·
Just opened the box and charged the unit now all I get is a white screen!!!!!
Powers up, but nothing but a white backlite screen????
By Mel Farrer <farrerfolks@...> · #19275 ·
Re: RF from outside - Did I brick my nanoVNA-H?
If it were mine, I would almost certainly try to repair it. Probably burned up a few cents to maybe a few dollars worth of parts, might take all of an hour to fix it. After fixing it, I would buy an
By Jim Allyn - N7JA · #19274 ·
Re: How to go to the FILE or WIKI page?
You need to be logged on to the website.? On Mon, 7 Dec 2020 at 5:06 PM, PE0CWK via groups.io<pe0cwk@...> wrote: Hi, As a member of this group I like to go the FILE page or the WIKI
By Larry Rothman · #19273 ·
How to go to the FILE or WIKI page?
Hi, As a member of this group I like to go the FILE page or the WIKI page, using the links which are found at [email protected] | Home </g/nanovna-users> When I click on the
By PE0CWK · #19272 ·
Re: My $165,000 VNA
Yes, the NANOVNA offerings are nothing short of a game changer and a wonderful educational tool. Once the (good) universities get word of them, they should be buying them by the hundreds for their RF
By W0LEV · #19271 ·
Re: NanoVNA-H low frequency errors #calibration #firmware #nanovna-h
Hi DiSlord, That is true, it is a big ask and I did consider that as being an issue. I have tried a couple of calibrations 50k to 2M and 1M to 900M. The lower frequency range still seems a little
By Leighton · #19270 ·
Re: NanoVNA-H low frequency errors #calibration #firmware #nanovna-h
Hi Larry, Thanks for the suggestion. I have tried a few things including the screen "RESET" button and also tried the "clearconfig" command also. I have also tried "blanking" the device with the
By Leighton · #19269 ·
Re: NanoVNA-H low frequency errors #calibration #firmware #nanovna-h
I not recommend use as start point 50k and end big frequency like 900M Better set 1M to 900M If need measure on < 1M select only this range. Interpolation for low values < 1M allow measure it on this
By DiSlord · #19268 ·
Re: NanoVNA, SAAV2+4, RigExpert
THANK YOU!!! Exactly what I needed, perfect! I definitely think I was making them a bit wrong, certainly not precise enough. I was making my center pin on the males too long among other things... I