¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Connect Antenna Trap to NanoVNA
The SARK-110 is an antenna analyzer. I know it's a tiny point of distinction, but one nonetheless.
By Danny K5CG · #17843 ·
Re: Strange problem with Dislord v1.0.39
Unfortunately I cannot reproduce the problem, I set the range 450-490, 460-475. Calibrated, everything went smoothly. I later added a reset of the generator cache when starting the scan, maybe this
By DiSlord · #17842 ·
Re: Strange problem with Dislord v1.0.39
Alan, Why not trying to increase the span by 10mhz at a time to see where you get correct readings? That may help to narrow down the issue.? On Thu, 1 Oct 2020 at 10:10 AM, Alan ¡°W2AEW¡±
By Larry Rothman · #17840 ·
Re: Strange problem with Dislord v1.0.39
Hello DiSlord, Thank you for the reply. I tried this procedure, and still have the same problem. I am not sure why. When I run through the calibration procedure over a wider span, it works
By Alan ¡°W2AEW¡± Wolke · #17839 ·
Re: Strange problem with Dislord v1.0.39
This is calibration issue. Reset device (off/on), load your calibration slot, and not made calibration reset, do only ISOLN/THRU after press done and save to slot. PS Firmware allow made apart
By DiSlord · #17838 ·
Re: Strange problem with Dislord v1.0.39
Does S21 look "normal" in uncalibrated state?
By Dragan Milivojevic · #17837 ·
Re: Strange problem with Dislord v1.0.39
Perhaps an open cable or a failed connection during calibration?
By Jerry Gaffke · #17836 ·
Re: Strange problem with Dislord v1.0.39
I just tried the previous version - same result - S21 very noisy, sitting well above 0dBm with both ports open. Strange.
By Alan ¡°W2AEW¡± Wolke · #17835 ·
Re: Strange problem with Dislord v1.0.39
Same version. Judging by the git logs, DiSlord regularly merges changes from H into H4 so the basic functionality should be the same. [email protected]> wrote:
By Dragan Milivojevic · #17834 ·
Re: Strange problem with Dislord v1.0.39
Same firmware? I believe the 2.8" unit has a 2.8" nanovna-H has an stm32f072cbt6 with 16kbytes of RAM vs an stm32f303cct6 on the nanovna-H4 with 40kbytes of RAM. And that for this reason the 2.8"
By Jerry Gaffke · #17833 ·
Re: Strange problem with Dislord v1.0.39
That is strange. Try the previous version ( https://github.com/DiSlord/NanoVNA-D/releases/tag/1.0.38) wrote:
By Dragan Milivojevic · #17832 ·
Re: Strange problem with Dislord v1.0.39
I did, several times. Reset and re-ran calibration over this narrow range, some result. If I use a cal over a much wider span, and rely on cal interpolation, it works. Just not if I cal over this
By Alan ¡°W2AEW¡± Wolke · #17831 ·
Re: Strange problem with Dislord v1.0.39
Used your settings on a 2.8" unit, same firmware. Everything works as expected. Did you try to reset the calibration? wrote:
By Dragan Milivojevic · #17830 ·
Strange problem with Dislord v1.0.39
I updated my -H4 with Dislord's latest v1.0.39 firmware, and for the most part it looks great - up to 401 points, adjustable measurement BW, etc. All good. However, I have a strange problem with it
By Alan ¡°W2AEW¡± Wolke · #17829 ·
Re: need a startup guide that describes the behavior of the LEDs on the side
You find hints in the manual in the Wiki. The RED led ( i think ), has the behavior of a USB power pack LED, because there is a power-pack chip (IP5303) in the Nano to charge the battery and a "watch
By ON1BES · #17828 ·
Re: Procedure for measuring S12 cable loss?
Let me clarify that scattering parameters expressed as return loss S11, imply a power measurement. Ken
By Ken Jamrogowicz · #17827 ·
Re: Calibration issue ?
The formulas were taken from G3TXQ spreadsheet so compare with it? If you are good with excel/libreoffice graphs you can mark the regions where Z > 2K and R > |X| (the desired resistive choke) same as
By Dragan Milivojevic · #17826 ·
Re: Calibration issue ?
Well, at last I've loaded my .s2p into excel and generate a graphic of my choke.. I would like to know how reliable is the whole thing..... Federico ik3umt
By Federico - ik3umt · #17825 ·
Re: Procedure for measuring S12 cable loss?
If the characteristic Z of the system is the same thru out, it matters not if you use 20log(Va/Vb) or 10log(Pa/Pb). Where the voltages or the powers are known.
By WB2UAQ · #17824 ·
Re: Calibration issue ?
Just make sure that you use the second version where ATAN2 is used for phase calculation.
By Dragan Milivojevic · #17823 ·