Calibration doesn't compensate for "open" correctly
I've been using the NanoVNA for a bit but I've found when calibrating, the "open" value isn't working reliably when using cables or when using extended adapters (like SMA extension for a male to male,
By
K9LUC
·
#10846
·
|
Re: How do you measure inductor values with nanovna?
Yes AL values of commercial toroids do vary quite a bit. I have found the need to add or subtract one or two turns to get the correct inductance values. Each mix is designed for a certain frequency
By
F4WCV
·
#10845
·
|
Re: Measuring CMC and S21 readings
Wouldn't you want to know what the resistive component of S21 is? Dale W4OP
By
Dale Parfitt
·
#10844
·
|
Re: PL-259 calibration
I was just looking into this the last few days to create a range of equipment I have SOL set and pleasantly see this message thread in my email. From my understanding, for above UHF work, the
By
jafinch78 .
·
#10843
·
|
Re: Measuring CMC and S21 readings
Hi, I do CMC-measurments by simply connecting the coax outer braid to the center of CH0 and CH1 and then trace 1 on LOGMAG and Channel 1 THROGH, see attached pictures. In my case the CMC is with
By
Torbj?rn Toreson
·
#10842
·
|
Re: Sma to alligator clip - ok for HF?
Clip leads rock ¡ª for audio. Larry's advice is excellent. Bear W5VZB
By
Bear Albrecht
·
#10841
·
|
Re: Firmware versions on a specific VNA version
In the files area, you will find the Console Commands document where the clearconfig command is explained. In the WIKI area, you will find references to all the firmware developers. Please refer to
By
Larry Rothman
·
#10840
·
|
Re: PL-259 calibration
Kevin, Take a look at the photo¡¯s at http://www.hamcom.dk/VNWA/SOT259%20calibration%20standards.pdf Robert PA7RG
By
PA7RG <robert.pa7rg@...>
·
#10839
·
|
Re: Firmware versions on a specific VNA version
Hello Larry, Firstly I do thank you very much for taking the trouble to reply. The answer to your first question is that I find nothing in the files area that is later than the versions that I have
By
Tony Jaques
·
#10838
·
|
Re: Measuring CMC and S21 readings
Hi Igor, I can help with the search by typing the key words "common mode choke impedance" or shorter will result in more results in the Search window. In the -F group, I see no such match. Great
By
Gyula Molnar
·
#10837
·
|
Measuring CMC and S21 readings
Hi, Does anybody use this device to measure common mode choke impedance? G3TXQ for instance suggested using |S21| and phase angle to recalculate X and R of the DUT in the spreadsheet. NANO VNA-F
By
Igor Lapko
·
#10836
·
|
Re: PL-259 calibration
Thanks! A great remember that realistically I won't notice much of a difference for the amount of work.
By
Kevin B
·
#10835
·
|
Re: PL-259 calibration
Kevin, don't worry so much about all this.? It's a hobby, and a PL-259 isn't so terrible that it will cause problems.? I have used them with good results up to 70 cm.? Type N is better but you
By
Bob Albert <bob91343@...>
·
#10834
·
|
Re: VNA Video Tutorial
The music makes the videos almost unbearable
By
K9LUC
·
#10833
·
|
Re: Which Chart(s) for Which Measurement(s)
RL = 10 log (Preflected/Pforward) = 20 log Rho= a negative qty because Preflected is < Pforward or Rho, the reflection coefficient is <1. But because it is a LOSS it is stated as positive.
By
WB2UAQ
·
#10832
·
|
Re: PL-259 calibration
I was going to switch them all to N connectors, on that note, is that still what's recommended? but then would have to do every radio and antenna. When I setup my new tower will probably make the
By
Kevin B
·
#10831
·
|
Re: PL-259 calibration
Be aware that PL259 / SO239 connectors are NOT impedance controlled! They are NOT appropriate for use at 70 cm! Even at 2-meters, they will introduce measurable loss in mismatches. They're OK for HF,
By
W0LEV
·
#10830
·
|
Re: PL-259 calibration
Thanks for the explanation and help. It will be primarily for 2m and 70cm. Based on the help looks like the best bet will be 2, 100s parallel.
By
Kevin B
·
#10829
·
|
Re: PL-259 calibration
What frequency will you be using? Two 100 ohm surface mount resistors opposite of each other has less inductance Mike N2MS
By
Mike N2MS
·
#10828
·
|
Re: PL-259 calibration
They recommend 2 100 ohm in parallel to reduce the stray capacitance that will distort the higher frequency results.
By
William Heller
·
#10827
·
|