Re: SAA2N reviews
On Wed, Sep 2, 2020 at 07:59 AM, Dragan Milivojevic wrote:
It would be nice if she would answer ...================================================== Dragan, I believe you sent your correspondence to Maggie at hugen's on-line store. OwO's official stores are on Taobao and Tindie. This group provides support for all V2 variants so OWO started another group that supports only the original V2 at /g/NanoVNAV2/ . You might ask about shipping to Serbia at that group, especially if you are intending on purchasing the original V2. -Herb |
Re: Dipole length
On Thu, 27 Aug 2020 at 18:50, Jerry Gaffke via groups.io <jgaffke=
[email protected]> wrote: Interesting plot here showing feed impedance vs height for a center fed I wish people would give the source of the information. The behaviour shown looks quite believable to me. One can show that the mutual impedance between dipoles follows a similar pattern. The formula is fairly complicated (more than I would want to put in email), but it includes either sine or cosine integrals (perhaps both), which shows a similar behaviour Note that the mutual impedance has both a real and imaginary part. I would expect not only the real part of the impedance to show this, but also the imaginary part. Dave --Dr. David Kirkby, Kirkby Microwave Ltd, drkirkby@... Telephone 01621-680100./ +44 1621 680100 Registered in England & Wales, company number 08914892. Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom |
Re: SAA2N reviews
It would be nice if she would answer ...
toggle quoted message
Show quoted text
I sent a message a while back asking why there is no shipping option for Serbia, when all surrounding countries are supported, and got no reply. Unless you are using NATO planes (only difference between Serbia and neighbouring countries) to deliver packages I see no reason why. On Wed, 2 Sep 2020 at 15:29, Hugen <hugen@...> wrote:
On Wed, Sep 2, 2020 at 08:49 PM, Hugo wrote:Yes, this is Maggie's shop. |
Re: SAA2N reviews ??
S-A-A-2 is a new design and not based on the original NanoVNA:
toggle quoted message
Show quoted text
It was open source which means there are many "clones" and variants on the market. Most of the clones perform fine, so you will be well served buying any random one on Aliexpress or Banggood. However if you want to support the original developers, only the stores listed on the above page will do that. On 02/09/2020 22:44, Mike Rhodes wrote:
Greetings, |
Re: SAA2N reviews ??
Greetings,
I am new to this group and totally unfamiliar with the nomenclature for the various models of NanoVNA. With that in mind, what, if any, is the difference between NanoVNA (including H4) and SAA2N ? I have an FA-VA5 and it works fine but there is hardly any activity on their reflector while this group seems to be very active so, here I am. Thanks, Mike / W8DN |
Re: SAA2N reviews
Hugo,
toggle quoted message
Show quoted text
I suggest you join /g/NanoVNA-V2 You will find more specific information regarding the SAA2 and their variants. Also some reviews about SAA2N. Cheers, Lu¨ªs CT2FZI A quarta, 2/09/2020, 06:08, Hugo <ve2_ugo@...> escreveu: So, you were able to test the 4 inch version with N connector and it has a |
Re: Crazy readings with nothing attached
#calibration
Hello they have all been checked and are working as they should be
thanks David |
Re: Crazy readings with nothing attached
#calibration
Problem in calibration units, cables
Check it better. |
Re: Crazy readings with nothing attached
#calibration
Hello after reset all looks good everything in the right place
|
Re: SAA2N reviews
So...
toggle quoted message
Show quoted text
First things first. Hugen does not sell on Tindie. One cannot compare nanoVNA-H with SAA2 firmware. What you said is not 100% correct, and it's user misunderstanding about the tool itself. V2 holds calibration and saves it. If you change frequencies either you recall again calibration or do calibration again. That is from OwO SW feature. I agree with it up to the point it reminds user that it's using different calibration for the frequency span. This feature was discussed already many times. About the display... I cannot understand who wants to use the display if nanovna-saver exponentially enhances the usability, including the saving of infinite calibration scenarios? ;) A quarta, 2/09/2020, 13:05, <aleks07111971@...> escreveu: This microbe has two problems! |
Re: Crazy readings with nothing attached
#calibration
Disable calibration (or reset)
You see noise after? if no - wrong calibration. If yes another problem (possibly hardware) |
Re: SAA2N reviews
On Wed, Sep 2, 2020 at 07:51 PM, Aleksander Shalygin wrote:
I haven't sold any products on "Tindy"? Are you sure you bought our products? |
Re: Crazy readings with nothing attached
#calibration
Hello i am using port 0
I have attached an image you can ee there its going crazy I have attached a pic of the version I will need to do some reading if i need to upgrade the version Nothing was soldered it is as it was delivered Thanks David |