Re: NanoVNA-Saver 0.2.0

vaclav_sal
 

On Tue, Nov 12, 2019 at 09:33 AM, Oristo wrote:


I am using the free STM32CUBEIDE from ST Micro the Mc manufacture
to build some SDR control code for a home project and it seems to work well.
Silly questions.
Can it be added to Eclipse IDE as "plug-in" ??

But it woudl make more sense , KISS, to use it as standalone IDE, right?

It woudl be easier to have both "running" and just switch between them as necessary.

I am just looking for real debugger IDE and STM32CUBEIDE seems to be the ticket.


Re: NanoVNA-Saver 0.2.0

vaclav_sal
 

On Tue, Nov 12, 2019 at 06:48 AM, Rune Broberg wrote:


I don't think there's any way to print anything to a standard console -
I was afraid of that.
That makes (C) code debugging little more complex than expected.
I'll work on that.
Thanks


Re: Now at Walmart

vaclav_sal
 

Stay far away from this 3rd party seller. There are typos all throughout their company info and their shipping policy looks strange and has many spelling mistakes as well.

Wow,
now we judge products by spelling errors.

Never mind that Wally's business model put many establishment where queens English was practiced out of business,
employs senior citizens etc.

How shallow can your get?

I am ordering mine from guess who?


Nanovna-Saver 0.2.0 MAC

 

The latest version seems to be working just fine on my mac.
Just remember with Catalina, the latest Python isn¡¯t working completely
so use an older version.

Dana VE3DS
Toronto Canada
where its going - 15C tonight


Re: Now at Walmart

 

Wow! Bright lights, movie stars.

- Herb


Re: Now at Walmart

 

Stay far away from this 3rd party seller.? There are typos all throughout their company info and their shipping policy looks strange and has many spelling mistakes as well.?



On Tue, 12 Nov 2019 at 8:12 PM, DuWayne Schmidlkofer<duwayne@...> wrote: I was browsing for something else when this link popped up.

--
DuWayne? KV4QB


Now at Walmart

 

I was browsing for something else when this link popped up.

--
DuWayne? KV4QB


Re: NanoVNA-Saver 0.2.0

 

Now that the capability is there in the software, how would one use the NanoVNA to check a toroid's permeability? New territory for me... :-)


Re: NanoVNA-Saver 0.2.0

 

@Tom VA7TA
Did you change "Display setup / Font / Font size" with too large font?
73, Lucio


Re: NanoVNA does not want to start -solved

 

Don't look too far. The chips can be found on Ebay. Search string: 10 PCS IP5305 SOP-8 IP 5305 IC CHIP
on1bes Herman


Re: DFUseDemo

 

I never had to use Zadig in Windows 10 64bit to use DFUseDemo. This is probably a problem by you. Put your Hardware Device Manager window on and examinate following. Try uninstalling Zadig (actually a USB driver) until it no longer appears in Hardware Devive Manager window. This may have to be done multiple times. In the View menu, put the option "show hidden devices", you will see them grayed out in the list, and see if there is an earlier installation of Zadig (Zadig itself is not visible, but 'USB lib device' or something similar - i have not the exact names, but don't delete the 'Universal Serial-Bus Controllers'!) delete or uninstall all gray drivers until they are gone. The Wiki Files contains the manual of DFUseDemo and its installation. Follow it carefully. I test it again here, and you don't need Zadig. If you connect the Nano, with the boot button pressed, a "STM Device in DFU Mode" will first appear in Hardware Device Manager (with a yellow triangle). If you wait 20 seconds, the driver is automatically loaded in Windows, and the "STM Device in DFU Mode" is added to the list "Universal Serial-Bus Controllers". If you turn the Nano off, "STM Device in DFU Mode" will remain in the list, but then turn gray.
on1bes


DFUseDemo

 

I am running Windows10 Home 64 Bit, and had DFUsDemo running OK
After a firmware update (Erics Version 2.3) suddenly DFUSE Demo no more sees my NanoVNA-H .
Windows devicemanager shows the the device in DFU mode as "STM32 Bootloader" and when I run Zadig I can select "STM32 Bootloader" and install the drivers.
In the device manager I see for "STM32 bootloader" these drivers : WinUSB.sys, WdfCoinstaller01011.dll and WinUSBcoinstaller2.dll are these correct ??
I uninstalled and re-installed DFUseDemo, whatever i do, nothing helps.
So now I can no more.update the firmware !
Is there anyone who can help to solve this problem ?
Many thanks in advance
Jos


Re: coax fatigue #test-jig

 

On Tue, Nov 12, 2019 at 09:37 AM, WB2UAQ wrote:

" Just wish it could measure higher impedances more accurately "

-----------------------------------------------------------------------------------------------------------

An HP8753 would not have helped you to measure higher impedances, I used one for years in my workplace and once you got too far off of 50 ohms the accuracy declined. In general, I believe that is true with all VNA's with a 50 ohm input impedance.

The HP8753 also started at 300 kHz which meant my company had to purchase a second VNA for lower measurements. I'd love to own a HP 8753 but I also know I can't afford the maintenance costs that would eventually be required.

- Herb


Re: coax fatigue #test-jig

 

Hi I'm a newbie when it comes to the NANOVNA but over the years I have been involved with many different aspects of radio both amuter and professional.
SMA connectors are not intended for repeated connection and reconnection, there is little or no strain relief with SMA connectors, use good quality connectors and cable, use large radius no sharp bends in test environment.
When the integrity of a connection is of concern (SMA connectors on NANO) and the connectors have to be connected or reconnected many times, for example in testing and re testing/integration it is common to fit additional sacrificial connectors to those on the unit (I have). This is to prevent damaging the connector's and can be replaced and still preserving the integrity of the main connector.

--
Raymond G8KPS


Re: coax fatigue #test-jig

 

I am thinking that the point of putting the nano in an enclosure is to stabilize the
poor isolation, not necessarily to eliminate it. But when the nano's leak is stabilized,
the ISOL CAL should then enable good correction.

This assumes that what goes outside the enclosure is done with good quality
cables (at least with respect to leakage) that are terminated. It would probably
help to terminate the ends in items that roughly duplicate the impedances that
the DUT will provide, although this is admittedly not very practical in most
cases.

BTW, SMA(M) cables that are left dangling with nothing connected can exhibit
wildly variable leakage from the ends. The center pin is coupled capacitively
to the nut, whose contact to the main body of the connector can range from only
fair to non-existent, depending on how it is laying (i.e., on what forces are acting
on the nut and from what directions, etc). RF leakage of this kind leads to RF
currents on the outside of the cable, which can resonate at various frequencies.
radiate to nearby cables that are similarly indisposed, etc. So even if you can't
spare good terminations, at least screw each cable end onto something that is
well-shielded for the isolation CAL step.

Dana


Re: NanoVNA-Saver 0.2.0

 

Hi Rune,

Many thanks again for your ongoing development of nanoVNA-Saver - fabulous work!

I am not sure if I should waste your time reporting this as it is not a significant issue....just apple polishing.

I noticed when I first start version 0.2.0 that the Center, Stop and Span frequency info within "Sweep Control" section overflows the window widths. At startup it displays 9 digits as shown below. Once I enter new sweep control frequencies it displays normally. However Center still overflows just a little. I have my sweep Stop set at 850M and the Center is showing 425.025MHz which just exceeds the window width by about a half digit. With initialization the data is about twice as wide as the window width with the most significant digits hidden from view then it reverts to normal upon receiving a new manual frequency entry.

Initialization displayed data:

SPAN 849.949952MHz
STOP 849.999952MHz
CENTER 425.024976MHz

Hope this feedback is useful.

--
Best Regards,
Tom
VA7TA


Re: Correction menu option ?

 

Why would you want to ever disable this?
When trying to evaluate / improve upon firmware calibration
by experiments with uncorrected data on hosts, e.g.
/g/nanovna-users/message/6696
/g/nanovna-users/message/6609
/g/nanovna-users/message/6600
/g/nanovna-users/message/6595
/g/nanovna-users/message/6484


Re: coax fatigue #test-jig

 

Thanks for doing the test Nick! I guess we are all having a great time working with this little unit. I was considering buying an 8753 and retrofitting it with an after-marked LCD display but I think for what I am doing now the Nanovna is all I need. Just wish it could measure higher impedances more accurately but when that is needed I have used my old General Radio bridges.


Re: NanoVNA-Saver 0.2.0

 

I am using the free STM32CUBEIDE from ST Micro the Mc manufacture
to build some SDR control code for a home project and it seems to work well.
I guess STM32CubeMX integration and STM support
are main claims to fame for STM32CUBEIDE,
which otherwise is another customization of ECLIPSE?/CDT IDE.

NanoVNA uses ChibiOS, which has a dedicated ECLIPSE?-based IDE,
namely ChibiStudio, and a utility for converting CubeMX output for ChibiOS


... which is already done for nanoVNA source, then STM32CUBEIDE seems
for ChibiOS firmware a step backwards from ChibiStudio


Re: errors of "error" models

 

[ann] next-to-come : on the measurement of s-parameters using the [LeastVNA] only