Re: Newbie NanoVNA question regarding calibration
Only had this for a few days. I don't know how to do any of what you suggested.
Connectors are tight. I didn't use cables with this calibration. I followed the guy in the video. I agree this does not look like the guy in the video outcome. he didn't have the lines extruding form the points. |
Re: Newbie NanoVNA question regarding calibration
Generator threshold value must be less then default 300M, need more detail see work in range 270 - 300M (reset calibration and see in this range)
From there threshold start problem. After write it to CONFIG->EXPERT SETTING->THRESHOLD After need save CONFIG->SAVE CONFIG |
Re: Newbie NanoVNA question regarding calibration
Here at the pics. The green lines are moving.You have no trace information or markers displayed. See the orange box below to see what I mean. If you did a software update you might need to do a Clear Config to flush out the old settings. It is under the expert settings and if you need a password it is 1234 Roger |
Re: Newbie NanoVNA question regarding calibration
try to do your sweeps with some averaging (means more points/values per measure point are takern and interpolated) ... that make the curves more even
toggle quoted message
Show quoted text
you even can do the calib with high avg .. and measure then with lower avg (on none at all) are your connectors tight?? what cable do you use?? are those values jumping around if you move cables a bit (wiggle on them)??? that you have those waves at the lower end and straight lines on the rest of the scan is not normal dg9bfc sigi Am 30.08.2022 um 19:11 schrieb TE Dukes: Thanks!! |
Re: Newbie NanoVNA question regarding calibration
HA!! Didn't know I could do that!!
Here at the pics. The green lines are moving. Thanks!! ![]()
Load_nanovna-h4_screen_2022-08-30_14-46-46.png
![]()
Open_nanovna-h4_screen_2022-08-30_14-45-16.png
![]()
Short_nanovna-h4_screen_2022-08-30_14-46-13.png
|
Re: Anything for Windows 7?
why not use w10?? ... most if not all software for w7 should also work on w10
toggle quoted message
Show quoted text
dg9bfc sigi Am 30.08.2022 um 19:39 schrieb Leif M: I still use W7 because most of my software is there. Nano VNA software for W7 would be nice too. |
Re: Newbie NanoVNA question regarding calibration
On Tue, Aug 30, 2022 at 10:11 AM, TE Dukes wrote:
Here are some screenshots of short, open and load after calibration. Post yours for comparison Roger |
Re: Newbie NanoVNA question regarding calibration
Thanks!!
I watched the video and did the calibration along with the guy. My menus are a little different than his. I don't have the choice of 'CORRECTION'. I think the equivalent on mine is 'Apply". Anyway, the points are where they are supposed to be BUT I have green lines coming out of each point jumping around. Pretty sure its not supposed to be doing that. Any ideas? Thanks |
Re: Newbie NanoVNA question regarding calibration
On 8/29/22 6:40 PM, TE Dukes wrote:
What I'm wanting to do is to check a dupexler I have coming in the next week or so to make sure its tuned close the frequencies I requested.My first guess is that the frequency range used for calibration is different than the frequency range used for the measurement. |
Re: Newbie NanoVNA question regarding calibration
I suggest you use the nanoVNA in stand-alone mode (without a PC) in order to test it out.
Do a calibration over a wide range like 50 kHz. to 900 MHz. and then check it using the cal loads and the Smith Chart. Short should be a dot on far left of horizontal axis 50 ohm load should be a dot in center of Smith chart Open should be a dot on far right of horizontal axis Watch this video for the complete procedure. Roger |
Re: NanoVNA App - Installation and Use
#applications
works fine here
toggle quoted message
Show quoted text
dg9bfc sigi Am 26.08.2022 um 12:32 schrieb Goebel, Klaus: I use the NanoVNA-App v1.1.209 (build by Owen Duffy) together with a NanoVNA V2Plus4 running the current DiSlord firmware (v1.3.07, see first screenshot). I noticed that coloured screenshots look strange (see second screenshot). Is there a workaround for this? |
to navigate to use esc to dismiss