Thanks for your very quick reply. That sorted it.
Paul, G0VKT.
toggle quoted message
Show quoted text
On Mon, 21 Oct 2019, 16:04 Rune Broberg, <mihtjel@...> wrote:
Hi Paul,
if you selected "yes" to automatic checking for updates, it only runs when
it has an Internet connection because of a bug. Sorry! 0.1.4 will fix this
issue :-)
If you open the NanoVNASaver.ini file the app tells you the location of
when you start it (in the console window), you can set the CheckForUpdates
setting to "No". I suggest setting it back when 0.1.4 comes out, though
:-)
--
Rune / 5Q5R
On Mon, 21 Oct 2019 at 17:01, Paul Sayer <paulsayer123@...> wrote:
The latest version only runs when I am connected to the internet. The
previous version works without. Have I done something wrong? Or is it
just
how it us?
Only had my nano a week. The software makes it much easier to use in ham
radio antenna measurements . Having sweep by band is a nice touch.
I appreciate the development efforts.
Thanks,
Paul, G0VKT
On Wed, 16 Oct 2019, 13:38 Rune Broberg, <mihtjel@...> wrote:
I just released NanoVNA-Saver 0.1.3!
This release adds a couple of much requested features:
Popout charts
All charts can now be popped out as separate windows: Right click them,
and
select "Popout chart" to get a copy of it. As a side effect of
implementing
this, the main window can now also contain multiple charts of the same
type. Want a zoomed in version of an existing chart next to it? Now you
can.
VSWR markers
Under Display setup, you now have the option of adding a number of VSWR
markers, to be shown on both the S11 Smith chart, the S11 Return Loss
chart, and obviously the S11 VSWR chart. The colour can be selected,
and
you can add however many you need. The markers are saved between
startups.
Logarithmic frequency span
All frequency-dependent charts can now be changed to show logarithmic
frequency span instead of linear. Right click, select Frequency axis,
and
choose linear or logarithmic.
Shortcuts
You can now start a new sweep by pressing Ctrl-W, or stop a sweep by
pressing Escape while within the main window.
Line thickness and point size
Line thickness and point size can now be configured within the Display
setup window. Default values are 1 pixel for lines, 2 pixels for data
points.
Additionally, there are minor changes, such as -60 dB points being
automatically estimated from -10 dB and -20 dB points when doing filter
analysis, and a number of bugfixes and stability improvements. This
version should also work better with the NanoVNA-F, though there may
still
be some niggles.
I look forward to hearing your feedback on the software, and I hope you
enjoy using it!
--
Rune / 5Q5R