Re: H4 + nanovna-saver calibration


 

There is a hook/mouse click "box" in nanosaver to reset any previous cal.
Look for it and click it.

Dave - W?LEV

On Tue, Apr 29, 2025 at 5:02?AM Fran?ois via groups.io <18471=
[email protected]> wrote:

Using nanaovna-saver, on a -f, I noticed that sometimes the circle on the
Smith machine (on a simple capacitor, for example) could be larger than the
grid circle.

Now, systematically, even before calibrating with nanaovna-saver, I
perform a RESET on the case, which nanovna-saver doesn't seem to do (0.3.8
because W7). This RESET solves the problem.
--
F1AMM