make the swr trace active and then press on calib (without recalibrating) and then save to slot 0 (default slot on boot up) ... i do the same if i want other settings to be saved (be it avg setting or number of points or whatever)

dg9bfc sigi

Am 22.04.2025 um 11:36 schrieb Torbj?rn Toreson via groups.io:

When I have made a calibration that firstly involves a SWR trace and secondly a trace for Smith, then the Smith-trace is the active trace. Is it possible to afterwards when having changed so that the SWR-trace is the active trace to save that change so when restarting the NanoVNA the SWR-trace is the active trace? Config > Save Config does not help. I realize that making the SWR-trace active before calibration and saving would accomplish that, but afterwards?
73/Torbj?rn/SM6AYM