Thank you very
much for the replies Martin. I found your write up to be quite
excellent and informative. Thank you for providing a link to it.
I have read it twice and noted several questions and wondered if I
may send you a PM regarding them plus some comments regarding
several possible omissions (and one tiny typo)?
Gedas, W8BYA EN70JT
Light travels faster than sound.....
This is why some people appear bright until you hear them speak.
On 11/1/2024 4:49 PM, Martin -
Southwest UK via groups.io wrote:
toggle quoted message
Show quoted text
Hi Gedas,
?
At VLF it makes less of a difference, as the inductive
reactance is such a small proportion of the loop impedance.
?
At mid-frequencies the value of inductance starts to become
significant.
?
Taking a 1m diameter loop
?
5mm diameter (thin) conductor the inductance is around 3.38uH
25mm diameter (typical) conductor the inductance is around
2.37uH
75mm diameter (very fat) conductor the inductance is around
1.68uH
?
At mid-frequencies, around 10MHz, I'd expect to see about 3dB
improvement between 5mm to 25mm and another 3dB between 25mm to
75mm
?
These are some notes I made a while ago. I may be wrong, but
nobody seemed to be that interested in challenging what I
wrote.?
?
?
Regards,
?
Martin