John,

Is this condition at all faucets and devices?

On my 410 I have flex lines both on the intake and discharge of the HWH. I have seen these kink and restrict water flow. The Mixing valve shouldn¡¯t have anything to do with the pressure since it¡¯s basically a flow thru device, cooling the water down, not restricting the HW. Another possibility is (depending on how old your HWH is) would be sediment buildup at the bottom of the tank restricting the incoming cold water. Drain the tank and see how fast the water comes out from the bottom then once it¡¯s low remove the fittings and drain into a small plate to see if there is any crap coming out.

?

Steve in Solomons MD

410 S2E

?