开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育

Re: 18MHz drain Voltage supply Bypass problem


Raul J Pla
 

Barry, Its doing a good 1KW on all other bands so the amp cannot be damaged.

R

On Mon, Sep 18, 2023 at 2:16?PM Barry K4OCS <KK4OCS@...> wrote:
If you have blown one or both of the LDMOS outputs your VSWR will be off and it will never load up going into bypass



Barry??


On Sep 18, 2023, at 2:11 PM, Raul J Pla <planet95x@...> wrote:

?
Thanks for the note.. however. Over power input is not the issue. I'm using 20 to 50 watts in.

The bypass error starts at 17 watts input

I never have put over 50w in on any band.

Raul
W4AWI

On Mon, Sep 18, 2023, 14:07 Barry K4OCS <KK4OCS@...> wrote:
I had the same problem with my ICOM 7300 I sent my LA 1K back to the factory after they replaced ?one of two LDMOS’s I had them install a new protect board that will put the unit in bypass if it sees anything more than 60 watts. I replace the ICOM with a Yaesu FTDX101D no more over shoot. that project board is not free but it’s very inexpensive.



Barry??


On Sep 18, 2023, at 1:11 PM, Joe Loverti WW8X <jloverti@...> wrote:

?
If you do a Google search you should see some reports on an overshoot anomaly?with the IC-7300. I didn't cure my intermittent bypass issues until I started using an FTDX-10. I don't know how widespread this issue is, but I know I had it. My IC-7300 played well with my AL80-B (tube amp) but not with the LA-1K (solid-state amp).
Joe
WW8X

On Mon, Sep 18, 2023 at 12:56?PM Raul J Pla <planet95x@...> wrote:
I started using my 2022 LA-1K this week in earnest. I was checking the power on each band as well as some CQs on CW or answering?some SSB CQs.
Testing bands 40m to 10m I found a problem on 17m (18MHz)

Running the IC-7300 with just 30-50W into the amp, I saw 900 to 1050W on all bands except 17m.

There it goes into bypass, even dropping power to 15W in 300W out I get the?+Vd bypass.? Going down to 10W in 200W lets it keep working..

I made a 4 min video and a couple of pictures in case Palstar needs to see this. Is there an internal adjustment I can do or some testing I can do inside to avoid the shipping to and from Palstar? The book only has this text below
Bypass+VD: [as seen on display] Amp is in BYPASS to protect from loss of +50V, drain voltage supply. The indication should clear in a few seconds. This occurs when operating on 120V, if Drain Current (Id) exceeds 32 Amps . Solution: Switch supply voltage to 240V, or If operating on 120V, Reduce Drive Power

Any?help, appreciated!

BTW I'm using the HF-Auto tuner as well. The antenna is at 1.8:1 and the tuner gets to 1.05:1 easy.

73
Raul? ?W4AWI

Join [email protected] to automatically receive all group messages.