Re: 18MHz drain Voltage supply Bypass problem


 

开云体育

Raul,

?

It still could be the issue and you wont really know until you put a scope on it. The LA1K will go into bypass with the slightest overshoot over 50 watts. The latest firmware.

?

That being said, the over shoot could still happen at lower power.

?

Barry

VE6UM

?

From: [email protected] <[email protected]> On Behalf Of Raul J Pla
Sent: September 18, 2023 12:11 PM
To: [email protected]
Subject: Re: [la1k] 18MHz drain Voltage supply Bypass problem

?

Thanks for the note.. however. Over power input is not the issue. I'm using 20 to 50 watts in.

?

The bypass error starts at 17 watts input

?

I never have put over 50w in on any band.

?

Raul

W4AWI

?

On Mon, Sep 18, 2023, 14:07 Barry K4OCS <KK4OCS@...> wrote:

I had the same problem with my ICOM 7300 I sent my LA 1K back to the factory after they replaced ?one of two LDMOS’s I had them install a new protect board that will put the unit in bypass if it sees anything more than 60 watts. I replace the ICOM with a Yaesu FTDX101D no more over shoot. that project board is not free but it’s very inexpensive.

?

?

Barry??

?



On Sep 18, 2023, at 1:11 PM, Joe Loverti WW8X <jloverti@...> wrote:

?

If you do a Google search you should see some reports on an overshoot anomaly?with the IC-7300. I didn't cure my intermittent bypass issues until I started using an FTDX-10. I don't know how widespread this issue is, but I know I had it. My IC-7300 played well with my AL80-B (tube amp) but not with the LA-1K (solid-state amp).

Joe

WW8X

?

On Mon, Sep 18, 2023 at 12:56?PM Raul J Pla <planet95x@...> wrote:

I started using my 2022 LA-1K this week in earnest. I was checking the power on each band as well as some CQs on CW or answering?some SSB CQs.

Testing bands 40m to 10m I found a problem on 17m (18MHz)

?

Running the IC-7300 with just 30-50W into the amp, I saw 900 to 1050W on all bands except 17m.

?

There it goes into bypass, even dropping power to 15W in 300W out I get the?+Vd bypass.? Going down to 10W in 200W lets it keep working..

?

I made a 4 min video and a couple of pictures in case Palstar needs to see this. Is there an internal adjustment I can do or some testing I can do inside to avoid the shipping to and from Palstar? The book only has this text below

Bypass+VD: [as seen on display] Amp is in BYPASS to protect from loss of +50V, drain voltage supply. The indication should clear in a few seconds. This occurs when operating on 120V, if Drain Current (Id) exceeds 32 Amps . Solution: Switch supply voltage to 240V, or If operating on 120V, Reduce Drive Power

?

Any?help, appreciated!

?

BTW I'm using the HF-Auto tuner as well. The antenna is at 1.8:1 and the tuner gets to 1.05:1 easy.

?

73

Raul? ?W4AWI