Re: Remoting the LA-1K - Easy


 

The relay is a double pole so it switches both sides of the 240 at the same time. It has two connectors for the 120v and 4 connections (2 for each of the 240 lines).? The coil on the relay is activated by 120 volts from the smart switch.? Since I operate the whole station remotely I can activate and deactivate the smart switches easily from the cell phone.?

Paul Sobon
1700 Bassett Street, #1904
Denver, CO 80202


On Wed, Dec 26, 2018, 7:39 AM BJN644 <bartnewhouse@... wrote:
Thanks for the reply Paul, that all makes sense except for the relay. How do you switch 240v with a 120v relay, are you just switching 1 leg of 120v ?