Re: Minimum Track Width for Very Long Tracks


 

The lines concerned are I2C clock and data, and yes, I will be
considering them as transmission lines. However, there's no point
laying something down that is electrically just fine if the board cannot
be manufactured reliably or the tracks break during assembly (it will
get bolted down, but before that happens someone will have to pick it up
and move it into position).

Chinese PCB houses can routinely achieve 0.15 mm on normal sized boards.
So am I worrying about nothing, because they will in fact have no
trouble with a track (say) 0.2 mm wide and 500 mm long, if that's what I
would choose from an electrical viewpoint?

Regards,

Robert.