No-one can tell by extra-sensory perception.

Upload your .ASC files AND all the other files required to run the simulation, but not? .RAW nor .LOG files, as a ZIP archive to Files => Temp and then tell us you did that.

======================================================================================
Best wishes John Woodgate OOO-Own Opinions Only

Rayleigh, Essex UK

I hear, and I forget. I see, and I remember. I do, and I understand. Xunzi (340 - 245 BC)


On 2023-05-01 14:11, brian wrote:

I have a design which is essentially two separate circuits (a motherboard and daughter card)?with two 3.3V rails (+3V3 and +3.3VP) and two separate grounds (GND and GND1). They do, however, use two instances of an ATMEGA808. The ATMEGA has Vdd and Vss power pints. When I update the symbol of the ATMEGA808 The schematic editor will alternately merge +3V3 and +3.3VP or GND and GND1.?

I do not know if this is a bug or if I am doing something wrong.

Thanks