At 12:12 AM +0000 8/9/02, original_black_bart wrote:
I've had an opportunity to test functionality of the AD4 file.
Programming via a Digitrax DB150, readback via PR-1. Values are sent
as expected. In reviewing the fle, I've noticed a few that
programming is permitted via paged mode. This needs to be changed as
the AD4 doesn't support such.
Thanks for checking!
Which modes work for it? I couldn't tell from the manual.
Trusting that it's okay with you and the readers of this NG, I'm
going to tinker around with the XML file to see if I can't format the
display a little better. For example,; indication of time in 1/10
seconds when setting a pulsed signal. Should be able to review and
respond on htis by Saturday.
Sounds great, thanks.
All of the formatting is in the "pane" section at the bottom of the "CVProducts_AD4.xml" file. Eventually, some of that should move to the programmer files, so that its common across multiple stationary decoders, but since we've just got the one now I put it all in the single file.
Bob
--
--------------
Bob Jacobsen (Bob_Jacobsen@..., 510-486-7355, fax 510-495-2957)
At CERN until August 10, replies may be slow.