jmri 5.10 automation no longer functions


 

开云体育


Loconet monitor data for train 1 crashing into train 2 sitting in b1

Tony

?
14:52:34.634: [A0 0C 00 53] ?Set speed of loco in slot 12 to 0.
14:52:34.853: [A0 01 00 5E] ?Set speed of loco in slot 1 to 0.
14:52:35.056: [A0 02 00 5D] ?Set speed of loco in slot 2 to 0.
14:52:35.446: [A0 05 00 5A] ?Set speed of loco in slot 5 to 0.
14:52:35.587: [A0 04 00 5B] ?Set speed of loco in slot 4 to 0.
14:52:35.681: [A0 06 00 59] ?Set speed of loco in slot 6 to 0.
14:52:36.181: [B2 06 70 3B] ?Sensor LS14 (B14 SENSOR) is High
14:52:49.948: [A0 03 00 5C] ?Set speed of loco in slot 3 to 0.
14:52:50.854: [EF 0E 7B 01 10 03 77 07 76 06 00 00 00 77] ?Request Fast Clock is Synchronized, Running, rate is 1:1. Day 6, 14:52. Last set by ID 0x00 0x00 (0).
??????Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available.
14:52:50.917: [B4 6F 7F 5B] ?LONG_ACK: Function not implemented, no reply will follow.
14:52:55.263: [B2 07 50 1A] ?Sensor LS15 (B15 SENSOR) is High
14:52:56.966: [B2 07 40 0A] ?Sensor LS15 (B15 SENSOR) is Low
14:53:04.062: [A1 03 00 5D] ?Set loco in slot 3 direction Forward F0=Off F1=Off F2=Off F3=Off F4=Off.
14:53:21.736: [A0 0D 00 52] ?Set speed of loco in slot 13 to 0.
14:53:24.658: [A0 0C 00 53] ?Set speed of loco in slot 12 to 0.
14:53:24.862: [A0 01 00 5E] ?Set speed of loco in slot 1 to 0.
14:53:25.081: [A0 02 00 5D] ?Set speed of loco in slot 2 to 0.
14:53:25.456: [A0 05 00 5A] ?Set speed of loco in slot 5 to 0.
14:53:25.596: [A0 04 00 5B] ?Set speed of loco in slot 4 to 0.
14:53:25.690: [A0 06 00 59] ?Set speed of loco in slot 6 to 0.
14:53:27.878: [A0 07 00 58] ?Set speed of loco in slot 7 to 0.
14:53:29.878: [BB 7B 00 3F] ?Request Fast Clock information.
14:53:29.893: [E7 0E 7B 01 64 07 77 07 76 06 00 00 00 0F] ?Response Fast Clock is Synchronized, Running, rate is 1:1. Day 6, 14:52. Last set by ID 0x00 0x00 (0).
??????Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available.
14:53:38.904: [A1 04 00 5A] ?Set loco in slot 4 direction Forward F0=Off F1=Off F2=Off F3=Off F4=Off.
14:53:38.904: [A0 04 40 1B] ?Set speed of loco in slot 4 to 64.
14:53:39.951: [A0 03 00 5C] ?Set speed of loco in slot 3 to 0.
14:53:41.280: [D0 20 02 27 1E 34] ?Transponder address 5022 present at LR3 () (BDL16x Board ID 1 RX4 zone B or BXP88 Board ID 1 section 3 or the BXPA1 Board ID 3 section).
14:53:41.498: [B2 01 50 1C] ?Sensor LS3 (B3 SENSOR) is High
14:53:43.014: [D0 00 01 27 1E 17] ?Transponder address 5022 absent at LR2 () (BXP88 Board ID 1 section 2 or the BXPA1 Board ID 2 section).
14:53:45.077: [B2 00 60 2D] ?Sensor LS2 (B2 SENSOR) is Low
14:53:45.615: [D0 20 03 27 1E 35] ?Transponder address 5022 present at LR4 () (BXP88 Board ID 1 section 4 or the BXPA1 Board ID 4 section).
14:53:45.818: [B2 01 70 3C] ?Sensor LS4 (B4 SENSOR) is High
14:53:46.380: [A0 03 40 1C] ?Set speed of loco in slot 3 to 64.
14:53:47.333: [D0 00 02 27 1E 14] ?Transponder address 5022 absent at LR3 () (BDL16x Board ID 1 RX4 zone B or BXP88 Board ID 1 section 3 or the BXPA1 Board ID 3 section).
14:53:49.630: [B2 01 40 0C] ?Sensor LS3 (B3 SENSOR) is Low
14:53:50.201: [D0 20 04 27 1E 32] ?Transponder address 5022 present at LR5 () (BDL16x Board ID 1 RX4 zone C or BXP88 Board ID 1 section 5 or the BXPA1 Board ID 5 section).
14:53:50.592: [B2 02 50 1F] ?Sensor LS5 (B5 SENSOR) is High
14:53:50.967: [EF 0E 7B 01 0F 03 78 07 76 06 00 00 00 67] ?Request Fast Clock is Synchronized, Running, rate is 1:1. Day 6, 14:53. Last set by ID 0x00 0x00 (0).
??????Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available.
14:53:51.029: [B4 6F 7F 5B] ?LONG_ACK: Function not implemented, no reply will follow.
14:53:51.967: [D0 00 03 27 1E 15] ?Transponder address 5022 absent at LR4 () (BXP88 Board ID 1 section 4 or the BXPA1 Board ID 4 section).
14:53:53.968: [B2 01 60 2C] ?Sensor LS4 (B4 SENSOR) is Low
14:53:54.655: [D0 20 05 27 1E 33] ?Transponder address 5022 present at LR6 () (BXP88 Board ID 1 section 6 or the BXPA1 Board ID 6 section).
14:53:56.203: [82 7D] ?Set Global (Track) Power to 'OFF'.
14:54:11.750: [A0 0D 00 52] ?Set speed of loco in slot 13 to 0.
14:54:14.672: [A0 0C 00 53] ?Set speed of loco in slot 12 to 0.
14:54:14.875: [A0 01 00 5E] ?Set speed of loco in slot 1 to 0.
14:54:15.094: [A0 02 00 5D] ?Set speed of loco in slot 2 to 0.