开云体育

Re: Signal Logic – Layout Editor Path Validation - Not Working - Please Help #sml #layouteditor


 

Spencer,

There are some errors during file loading:

21:30:00,110 configurexml.DefaultTransitManagerXml WARN? - When loading configuration - missing Section in Transit IZ:AUTO:0006 [AWT-EventQueue-0]
21:30:00,120 jmri.implementation.VirtualSignalMast WARN? - attempting to set an aspect that has been disabled: Stop on mast: SUC-15 North [AWT-EventQueue-0]
21:30:18,355 lay.configurexml.PositionableLabelXml INFO? - PositionableLabel? removed for url= home:OneDrive/train/Basement/Track plans/Outer-and-Inner-loop_SCARM---2022-Final-12-29-2022-Blocks-Recovered11-30-2024-Recovered-Recovered.jpg [AWT-EventQueue-0]
21:30:25,255 lay.configurexml.PositionableLabelXml INFO? - PositionableLabel? removed for url= home:OneDrive/train/Basement/Track plans/Upper-loop-block-names-v2.jpg [AWT-EventQueue-0]

You cannot have both Entry/Exit and Dispatcher controlling the layout. ?They both want to be in charge. ?You might be able to "Disable" the Entry/Exit sensor pairs when trying to use Dispatcher. ?I have not tested this concept.

“Signal Mast “SUC-19 West” is not reachable from “SUC-22 West”. ?This error is because you need to add "SUC-22 to UC-21" first.

The direction sensor errors are signal masts that don't have SML based sections.

I was able to delete?SU21V2.

Dave Sand



----- Original message -----
From: "ssellmaker via groups.io" <ssellmaker=[email protected]>
Subject: [jmriusers] Signal Logic – Layout Editor Path Validation - Not Working - Please Help #automation #blocks #blocktracking #dispatcher #entryexit #layouteditor #sensors #signalmasts #signals #transits
Date: Sunday, January 19, 2025 9:22 PM

Hello, I am struggling and need assistance please. My layout file is included. Please let me know if you need any additional information.

I am trying to setup automatic signaling using SML on my layout, for now, I am only focusing on the “Upper Level” Panel in the JMRI Layout Editor.

?

When I attempt to create a Transit from one signal to the other, I get the error “Signal Mast “SUC-19 West” is not reachable from “SUC-22 West”. Mast Will not be added.”, this seems to occur whenever asking it to route across turnouts and not limited to these signals.

I have current detectors on every block illustrated on the “Upper Panel” and these are working properly in the Layout Editor (blocks are showing occupied when current is detected). All turnouts have physical decoders and work properly. I would like to get some basic automatic running configured on the Upper Level and then apply the same logic to the Lower Level.

?

The block routing looks correct in the Routing Table, I have defined virtual sensors for the entry and exits. I also have virtual sensors configured for the direction (not sure if they are configured correctly, could this be the problem?). All checks under the Tools -> Check return “No Result” so all seems good here. Signal Masts are defined virtually for now, but they will control physical lights on the layout in the next phase. Signal Mask Logic was all auto generated (including sections), some sections I defined manually however.

?

I get the following errors when selecting “Add Direction Sensors to SML”

?

21:40:28,076 implementation.DefaultSignalMastLogic ERROR - Mast[SUC-24 North] No Associated Section [AWT-EventQueue-0]

21:40:28,076 implementation.DefaultSignalMastLogic ERROR - Mast[SUC-13 South] No Associated Section [AWT-EventQueue-0]

21:40:28,077 implementation.DefaultSignalMastLogic ERROR - Mast[SUC-24 North] No Associated Section [AWT-EventQueue-0]

21:40:28,077 implementation.DefaultSignalMastLogic ERROR - Mast[SUC-24 North] No Associated Section [AWT-EventQueue-0]

21:40:28,077 implementation.DefaultSignalMastLogic ERROR - Mast[SU1-2 East] No Associated Section [AWT-EventQueue-0]

21:40:28,078 implementation.DefaultSignalMastLogic ERROR - Mast[SU1-3 West] No Associated Section [AWT-EventQueue-0]

?

Other Problems that might be related:

?

I am also unable to remove the Signal Mast “SU21V2” from the Signal Mast Table.

?

Block “UC-24” shows a value of “Mack” (this is the name of a locomotive I was trying to send to this block previously) and I am not sure how to remove this?

?

I apologize for the wall of text, hopefully, someone can help me troubleshoot these issues and point me in the right direction.

?

Thanks,

Spencer


Attachments:
  • ZSA-CEN Railroad V0.005.xml
  • WarrantPreferences.xml

Join [email protected] to automatically receive all group messages.