Dan,
My first idea is to create a new turnout in JMRI and reverse the event numbers. ?Once that is done, move the user name from the old one to the new one. ?When everything works, delete the old turnout entry.
Another idea is to change the CDI definition for the output actions.
Dave Sand
toggle quoted message
Show quoted text
----- Original message -----
From: Daniel Kubarych <danandsharek@...>
Subject: [jmriusers] Inverted option grayed out in turnout table
Date: Sunday, December 01, 2019 12:05 AM
Hello:
Not sure if this is a JMRI question or an LCC question...
Have a small number of turnouts that where we need to change the closed and thrown positions. Of course we could change the wires connecting pin #1 and #8 on the tortoise .? To avoid climbing under the layout, we decided to use the inverted option in the turnout table.? That option is grayed is grayed out.? The documentation states that turnouts that cannot be inverted will be grayed out.? These turnouts use tortoises wired to an RR-Cirkits BOD4-CP installed on a Signal LCC card. The turnouts were created using the Create turnout feature in the OpenLCB CDI menu item.? There is also a sensor defined to monitor turnout position. What would cause the inverted selection in the turnout table to be grayed out?
Dan Kubarych
ARHS