Dan,

On 25 Nov 2019, at 1:05 PM, Dan Boudreau <daboudreau@...> wrote:

Valid cab addresses (for cabs in) a Powercab system are 2,3,4, or 5. Total of 4 actual cabs. 6 and 7 are unused. 8,9 and 10 can be used for other cab devices (AIU,USB) only.

?Valid cab addresses (for cabs) in an SB5 system are 2,3,4,5, 6 and 7. Total of 6 actual cabs. ?8,9 and 10 can be used for other cab devices (AIU,USB) only.

?If the AIU cab address is higher than 10 it will not work due to the limits of the command stations.


Correct, but there's further qualification needed regarding firmware versions:

If your Power Cab firmware (second screen at startup of your Power Cab, after the "Pro Cab V1.3" message) is:
- "V1.28C" the only valid addresses for extra cabs are 3 & (unofficially) 4.
- "V1.65" the only valid addresses for extra throttles ?are 3, 4 and 5. Non-throttle devices such as the NCE USB, Mini Panel or AIU can also use addresses 8, 9 & 10. However if you have ever done a System Reset, you will have lost all the extra addresses and be back to the V1.28C restrictions.
- "V1.65B" the only valid addresses for extra throttles ?are 3, 4 and 5. Non-throttle devices such as the NCE USB, Mini Panel or AIU can also use addresses 8, 9 & 10.

Similar ?comments apply to the SB3/5 with the range 2-5 for V1.28 and 2-7 for V1.65B.

Dave in Australia

Join [email protected] to automatically receive all group messages.