On 20 Sep 2019, at 1:44 PM, forfoum@... wrote:

Not what I said. I asked what would occur if CV1 = 66 and CV19 = 66. And I tested it and the decoder accepts this. Now the Command Station sends out commands to Address 66... So which will it be ? the Standard address or the Consist address ? CV19 takes precedence over others and I do not see the Command Station changing this based on which throttle.
CV1 and CV 66 are both short addresses. With that configuration, the only way to make the loco move is to send short address 66 speed packets. Having a non-zero CV19 overrides anything in CVs 1, 29, 17 or 18 as far as speed packet receptivity is concerned.

<>

Dave in Australia