What this is saying is that the Fleischmann Twin-Center sw ver. 2.000 doesn¡¯t use the same message sequence as (most) other Digitrax command stations, but rather the special set we first encountered for the IB-COM. JMRI knows about those (that¡¯s why it can interpret them), but just doesn¡¯t expect the Twin-Center sw ver. 2.00 to need them.
Is there a version 1 that works differently?
How have you got your JMRI connection and command station options set?
Bob
On Jan 11, 2019, at 10:10 AM, cocco.bill.97@... wrote:
18:58:09.896: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] Byte Read in Paged Mode on Service Track: CV8.
18:58:17.910: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] Byte Read in Paged Mode on Service Track: CV8.
18:58:25.931: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] Byte Read in Paged Mode on Service Track: CV8.
18:58:43.925: [83 7C] Set Global (Track) Power to 'ON'.
18:58:43.945: [83 7C] Set Global (Track) Power to 'ON'.
and this is what the Monitor says when I read CV 1 from the TC keypad:
19:02:34.553: [E5 07 01 49 42 41 56] Uhlenbrock IB-COM / Intellibox II Start Programming Track.
19:02:43.240: [ED 1F 01 49 42 71 72 01 00 2C 70 00 00 00 00 10 01 00 2C 00 00 00 00 00 00 00 00 00 00 00 64] Read CV in Direct Byte Mode from PT for Uhlenbrock IB-COM / Intellibox - CV: 1.
19:02:43.240: [81 7E] Master is busy.
19:02:43.247: [B4 6F 01 25] LONG_ACK: The Slot Write command was accepted.
19:02:46.808: [E7 0E 7C 00 00 00 72 07 00 1C 2C 7F 7F 2F] Programming Response: Uhlenbrock IB-COM / Intellibox II Programming Read Was Successful: CV29 value 44 (0x2C, 00101100b).
19:02:50.547: [E5 07 01 49 42 40 57] Uhlenbrock IB-COM / Intellibox II Stop Programming Track.
Note that the first and last messages appear respectively when I enter and exit programming mode on the Twin-Center, that is when the relay clicks.
I hope this information can help, looking forward to hear news :)