Ken,
Thanks. I had an idea that that was the problem. However, nothing is selectable as Internal under Defaults. Everything defaults to XpressNet (except Service Programmer and Ops Mode Programmer, both of which are greyed out - but I would expect that with the Compact).
Everything seems to work OK though. The annoying thing that happens is that, when opening JMRI, I get an error message and have to wait for Help and Preferences to open (automatically). Then I can continue.
Cheers
Tom
toggle quoted message
Show quoted text
On 24/12/2018 14:33, Ken Cameron wrote:
Tom,
Your log shows you opening the serial port ok, but then it doesn't like what
is happening with setting up the controls. Please check
Edit->Preferences->Defaults, they should not be selecting Internal but might
be doing that. Changing them to your system connection would fix that. The
rest of the errors trace to the initial one about not establishing a command
station correctly.
-Ken Cameron, Member JMRI Dev Team
www.jmri.org
www.fingerlakeslivesteamers.org
www.cnymod.com
www.syracusemodelrr.org